Component identification 10
Mezzanine connector definitions
Item PCIe
Mezzanine connector 1 x8, Type I mezzanine card only
Mezzanine connector 2 x8, Type I or II mezzanine card
System maintenance switch
Position Function Default
1* iLO 3 security override Off
2 Configuration lock Off
3 Reserved Off
4 Reserved Off
5* Password disabled Off
6* Reset configuration Off
7 Reserved Off
8 Reserved Off
9 Reserved Off
10 Reserved Off
*To access redundant ROM, set S1, S5, and S6 to ON.
System maintenance switch procedures
When you perform troubleshooting steps, this guide may instruct you to perform the following procedures:
Clear the system configuration ("Clearing the system configuration" on page 10).
Access the redundant ROM ("Accessing the redundant ROM" on page 11).
To complete these procedures, you must change physical settings on the system maintenance switch.
Clearing the system configuration
RBSU can be used to restore the factory default configuration. For more information, see "HP ROM-Based
Setup Utility (on page 50)." If the system is unable to boot into RBSU, use the following steps to clear the
system configuration:
1. Power down the server blade (on page 13).
2. Remove the server blade (on page 14).
3. Remove the access panel (on page 15).
4. Change position 6 of the system maintenance switch to on.
5. Install the access panel (on page 15).
6. Install the server blade in the enclosure and power up the server blade.
7. Wait for the POST message that prompts you to change the switch setting:
Maintenance switch detected in the "On" position.
Power off the server and turn switch to the "Off" position.