Software and configuration utilities 58
SmartStart assists the deployment process by performing a wide range of configuration activities, including:
Preparing the system for installing "off-the-shelf" versions of leading operating system software
Installing optimized server drivers, management agents, and utilities automatically with every assisted
installation
Testing server hardware using the Insight Diagnostics Utility ("HP Insight Diagnostics" on page 64)
Installing software drivers directly from the CD. With systems that have Internet connection, the
SmartStart Autorun Menu provides access to a complete list of ProLiant system software.
Enabling access to the Array Configuration Utility (on page 60) and Erase Utility (on page 63)
SmartStart is included in the HP Insight Foundation suite for ProLiant. For more information about SmartStart
software, see the HP Insight Foundation suite for ProLiant or the HP website
(http://www.hp.com/go/foundation).
HP ROM-Based Setup Utility
RBSU is a configuration utility embedded in ProLiant servers that performs a wide range of configuration
activities that can include the following:
Configuring system devices and installed options
Enabling and disabling system features
Displaying system information
Selecting the primary boot controller
Configuring memory options
Language selection
For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or
the HP website (http://www.hp.com/support/smartstart/documentation).
Using RBSU
To use RBSU, use the following keys:
To access RBSU, press the F9 key during power-up when prompted.
To navigate the menu system, use the arrow keys.
To make selections, press the Enter key.
To access Help for a highlighted configuration option, press the F1 key.
IMPORTANT: RBSU automatically saves settings when you press the Enter key. The utility does
not prompt you for confirmation of settings before you exit the utility. To change a selected setting,
you must select a different setting and press the Enter key.
Default configuration settings are applied to the server at one of the following times:
Upon the first system power-up
After defaults have been restored
Default configuration settings are sufficient for proper typical server operation, but configuration settings can
be modified using RBSU. The system will prompt you for access to RBSU with each power-up.