Hp Integrated Lights-Out 2 User Manual Page 183

  • Download
  • Add to my manuals
  • Print
  • Page
    / 224
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 182
Failure indicatedDescriptionPOST code (activity
completed)
LED indicator
Subsystem startup failed.Main_init() completed.00None
Flashes as the iLO 2
processor executes firmware
HB and 7
code. It does not change the
value of the lower six LEDs.
The iLO 2 microprocessor firmware includes code that makes consistency checks. If any of these
checks fail, the microprocessor executes the FEH. The FEH presents information using the iLO 2
POST LED indicators. The FEH codes are distinguished by the alternating flashing pattern of the
number 99 plus the remainder of the error code.
ExplanationConsistency checkFEH code
An RTOS function was called with an inappropriate value or from
an inappropriate caller.
TXAPICHK9902
The saved context of one or more threads has been corrupted.TXCONTEXT9903
A stack probe failed, the return address is invalid, or an illegal trap
instruction has been detected.
TRAP9905
An unexpected write to low memory has occurred.NMIWR9966
The reset vector has been modified.CHKNULL99C1
Event log entries
Event log explanationEvent log display
Displays when the server power fails.Server power failed
Displays the IP address for the browser that logged in.Browser login: IP address
Displays when the server power is restored.Server power restored
Displays the IP address for the browser that logged out.Browser logout: IP address
Displays when the server is reset.Server reset
Displays when a browser login fails.Failed Browser login—IP Address: IP address
Displays when iLO 2 has failed an internal test. The
probable cause is that a critical component has failed.
Further use of iLO 2 on this server is not recommended.
iLO 2 Self Test Error: #
Displays when iLO 2 is reset.iLO 2 reset
Displays when the onboard clock is set.On-board clock set; was #:#:#:#:#:#
Displays when the server logs critical errors.Server logged critical error(s)
Displays when a user clears the event log.Event log cleared by: User
Displays when iLO 2 is reset to the default settings.iLO 2 reset to factory defaults
Displays when the ROM has been upgraded.iLO 2 ROM upgrade to #
Displays when iLO 2 is reset for the ROM upgrade.iLO 2 reset for ROM upgrade
Displays when iLO 2 is reset by user diagnostics.iLO 2 reset by user diagnostics
Displays when the power is restored to iLO 2.Power restored to iLO 2
Event log entries 183
Page view 182
1 2 ... 178 179 180 181 182 183 184 185 186 187 188 ... 223 224

Comments to this Manuals