Table 46 Typical SIMs Showing the Reference Code and SIM Type
SVP Log FileSIM Generated
By
DescriptionSeverityReference Code
Byte 23Byte 22
SIM LogPrimary/secondary
storage system
Logical path is blocked due to a failure.Moderate8021
SSB LogPrimary/secondary
storage system
Logical path is restored.Service8121
SIM LogPrimary/secondary
storage system
Line failure is reported by the extender.Moderate8221
SIM LogPrimary storage
system
A volume being used by the primary data
volume has been suspended.
Serious0XDC
Path recovery is impossible.
SIM LogPrimary storage
system
A volume being used by the primary data
volume has been suspended.
Serious1XDC
A failure has been detected in the primary
storage system.
SIM LogPrimary storage
system
A volume being used by the primary data
volume has been suspended.
Serious2XDC
A failure has been detected in the
secondary storage system.
SIM LogPrimary storage
system
A volume being used by the primary data
volume has been suspended.
Serious4XDC
A data volume pair has been suspended
at the secondary storage system.
SIM LogPrimary storage
system
A volume being used by the primary data
volume has been suspended.
Serious5XDC
A data volume pair has been released at
the secondary storage system.
SIM LogPrimary storage
system
A volume being used by the secondary
data volume has been suspended.
Serious6XDC
Path recovery is impossible.
SIM LogSecondary
storage system
A volume being used by the secondary
data volume has been suspended.
Serious7XDC
A failure has been detected in the
secondary storage system.
SIM LogPrimary storage
system
A volume being used by primary data
volume has been suspended.
A failure has been detected in the primary
storage system.
Serious9XDC
SIM LogPrimary storage
system
A volume used as a P-VOL in an XP
Continuous Access Journal system made
SeriousAXDC
up of multiple primary and secondary
storage systems combination has been
suspended.
A failure has been detected in other
primary and secondary storage systems.
Checking Service Information Messages (SIMs) 239
Page view 238

Comments to this Manuals

No comments