4. Confirm that the data was correctly backed up to tape.
Execute the drmtapecat command on backup server A to check whether there exists backup
catalog information for the date that the backups from the primary volumes to the secondary
volumes were performed:
BKServer A > drmtapecat -backup_id 0000000002
BACKUP-ID BACKUP-OBJECT SNAPSHOT TIME EXPIRATION TIME BACKUP-MEDIA
0000000002 MSEXCHANGE 2007/11/01 11:00:00 2007/11/01 11:30:00 MEDIA1
BKServer A >
Execute the drmtapecat command on backup server B to check whether there exists backup
catalog information for the date that the backups from the primary volumes to the secondary
volumes were performed:
BKServer B > drmtapecat -backup_id 0000000012
BACKUP-ID BACKUP-OBJECT SNAPSHOT TIME EXPIRATION TIME BACKUP-MEDIA
0000000012 MSEXCHANGE 2007/11/01 11:00:00 2007/11/01 11:30:00 MEDIA1
BKServer B >