1. Install the sendmail-cf RPM from your operating system distribution media, if it is not
already installed.
2. If you are running with a firewall, the sendmail firewall port 25 must be open by adding
the following line to /etc/sysconfig/iptables before the final COMMIT line:
-A RH-Firewall-1-INPUT -m state --state NEW -m tcp -p tcp --dport 25 -j ACCEPT
3. Restart the firewall:
# service iptables restart
4. Make sure a fully qualified host name for the server node is present in /etc/hosts.
5. To send mail to an email address non-local to the HP-SFS servers, domain name service on
the node must be correctly set up to access your default network SNMP mail server. This is
typically done by setting up the correct information in /etc/resolv.conf.
6. Add a line to the /etc/mail/access file for each MSA controller IP address. For example:
192.168.16.101 RELAY
7. Add dnl to the /etc/mail/sendmail.mc file to allow non-localhost email.
dnl DAEMON_OPTIONS('Port=smtp,Addr=127.0.0.1, Name=MTA')dnl
8. On some systems, you might need to specify an external mail server by removing dnl from
the following line and specifying the SMTP mail server:
define('SMART_HOST', 'smtp.your.provider')dnl
9. # cd /etc/mail
10. # make
11. # service sendmail restart
You should now be able to designate an HP SFS server as a mail server in the MSA configuration,
and it should work correctly. If there are problems, check the /var/log/maillog file for
debugging information. If you are using an existing mail server, you might need to follow a
procedure similar to that described above on the existing mail server. Work with your system
administrator to resolve any additional configuration modifications that might be required for
your specific local network and security configuration.
2.4.2 SNMP Monitoring
If there is an SNMP management system present on the network containing the MSA, the MSA
can report status information and traps through SNMP. On the MSA2000, this is controlled
primarily through the set snmp-parameters CLI command or GUI. To complete the setup
of SNMP monitoring, see the MSA2000 documentation and the documentation for your SNMP
management system.