Hp StorageWorks 500 Modular Smart Array User Manual Page 78

  • Download
  • Add to my manuals
  • Print
  • Page
    / 157
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 77
Configuration and Utilities
HP StorageWorks Modular Smart Array 500 System User Guide 4-15
Drive status messages include:
Interim Recovery: The logical drive is operating, but a failed drive has not been
replaced. Replace drive as soon as possible.
Ready for Recovery: The logical drives are queued for recovery. This status is
displayed when another logical drive is already rebuilding or expanding.
Rebuilding: The array is operating and rebuilding a replacement drive or an
online spare, if one was assigned.
Logical Drive Failed: If you have one or more logical drives that are not
protected by fault tolerance in an array, the data on these logical drives will be
lost. ACU shows the logical drives as FAILED. After drive replacement, any
fault-tolerant logical drives rebuild. The logical drives that were not protected
(FAILED) become available for data (the devices are reactivated automatically).
If you have a backup of the data, restore the data now.
If you do not replace the failed drive, the only option using ACU is to delete
logical drives. Do not delete logical drives that contain valid data. Doing so
results in data loss.