Job monitoring Page 109 of 135
Connection, Operations in replication queue
The number of replication operations in the source queue
Connection, Operations received
The number of operations received by the target since the last
Performance Monitor refresh
Connection, Operations resent
The number of operations re-sent since the last time the Storage Mirroring
service was restarted on the source
Connection, Operations transmitted
The number of operations transmitted from the source
Connection, Task commands queued
The number of task commands queued on the source
Connection, Task commands submitted
The number of task commands submitted on the source
Connection, Tasks failed
The number of task commands that have failed to execute on the source
Connection, Tasks ignored
The number of task commands that have been ignored on the source
Connection, Tasks succeeded
The number of task commands that have succeeded on the source
Kernel, Activation code failures
The number of activation code failures when loading the source or target,
since the last time the Storage Mirroring service was restarted on the
source
Kernel, CRCRead Time
The length of time, in microseconds, spent reading CRC (cyclic
redundancy check) data on the target. If this value is longer than the
standard access time of the target's storage device, it indicates there is
possibly an issue reading the data on the target. For example, if the target
storage is a SAN, there may be an issue with the way the SAN is
configured.