Hp Virtual Connect Enterprise Manager Software User Manual Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 111
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
d. To disable trap severities, from the Add a SNMP Trap Destination page, click Advanced, as
shown in the following figure.
Figure 3-4 Disabling trap severities
e. Trap categories must equal Other for either VC-Enet traps or VC-FC traps. Do not select both.
From the Add a SNMP Trap Destination page, click Advanced, click More, and then select
either of the following:
On the VC-Enet Traps box, select Other, as shown in the following figure.
On the VC-FC Traps box, select Other.
Figure 3-5 Selecting trap categories
f. To disable Virtual Connect Manager traps, from the Add a SNMP Trap Destination page,
click Advanced, and then click More. The right side must be empty, as shown in the following
figure.
VC Domains 27
Page view 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 110 111

Comments to this Manuals

No comments