HP BladeSystem
HP BladeSystemHP BladeSystem
HP BladeSystem
p-Class Server Blade
p-Class Server Bladep-Class Server Blade
p-Class Server Blade
Enclosure
EnclosureEnclosure
Enclosure
Dimensions
DimensionsDimensions
Dimensions
Height
10.5 in (26.67 cm)
Width
17.60 in (44.70 cm)
Depth
28.86 in (73.30 cm)
Input Specifications
Input SpecificationsInput Specifications
Input Specifications
Rated input voltage
-43 VDC to -53 VDC
Nominal -48 VDC
Rated input current
62.5 A at -48 VDC
Rated input Power
3000 W
Individual Server Blade
Individual Server BladeIndividual Server Blade
Individual Server Blade
Bay Ratings
Bay RatingsBay Ratings
Bay Ratings
Rated input voltage
-43 VDC to -53 VDC
Nominal -48 VDC
Rated input current
6.25 A at -48 VDC
Rated input Power
300 W
Temperature Range
Temperature RangeTemperature Range
Temperature Range
Operating
50° to 95° F (10° to 35° C)
Non-Operating
-22° to 140° F (-30° to 60° C)
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
(non-condensing)(non-condensing)
(non-condensing)
Operating
20% to 80%
Non-Operating
5% to 95%
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
Wet Bulb Temperature
Operating
82.4° F (28° C)
Non-Operating
101.7° F (38.7° C)
NOTE:
NOTE: NOTE:
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
HP BladeSystem
HP BladeSystemHP BladeSystem
HP BladeSystem
p-Class Server Blade
p-Class Server Bladep-Class Server Blade
p-Class Server Blade
Enclosure with enhanced
Enclosure with enhancedEnclosure with enhanced
Enclosure with enhanced
backplane components
backplane componentsbackplane components
backplane components
Dimensions
DimensionsDimensions
Dimensions
Height
10.5 in (26.67 cm)
Width
17.60 in (44.70 cm)
Depth
28.86 in (73.30 cm)
Input Specifications
Input SpecificationsInput Specifications
Input Specifications
Rated input voltage
-43 VDC to -53 VDC
Nominal -48 VDC
Rated input current
125 A at -48 VDC
Rated input Power
6000 W
Individual Server Blade
Individual Server BladeIndividual Server Blade
Individual Server Blade
Bay Ratings
Bay RatingsBay Ratings
Bay Ratings
Rated input voltage
-43 VDC to -53 VDC
Nominal -48 VDC
Rated input current
14.6 A at -48 VDC
Rated input Power
700 W
Temperature Range
Temperature RangeTemperature Range
Temperature Range
Operating
50° to 95° F (10° to 35° C)
Non-Operating
-22° to 140° F (-30° to 60° C)
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
(non-condensing)(non-condensing)
(non-condensing)
Operating
20% to 80%
Non-Operating
5% to 95%
Wet Bulb Temperature
Wet Bulb TemperatureWet Bulb Temperature
Wet Bulb Temperature
Operating
82.4° F (28° C)
Non-Operating
101.7° F (38.7° C)
NOTE:
NOTE: NOTE:
NOTE:
Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
QuickSpecs
HP ProLiant BL25p Server Blade
HP ProLiant BL25p Server BladeHP ProLiant BL25p Server Blade
HP ProLiant BL25p Server Blade
Technical Specifications
DA - 12160 North America — Version 7 — June 27, 2005
Page 37
Page view 36