The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellence
and 2U density for a variety of rack deployments and applications.
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Access panel
1.
Redundant Power Supply Bay (Optional)
2.
Front LED Indicators
2.
Power Supply Cable Socket
3.
Power on/off
3.
Low Profile Card Slot
4.
Optional DVD-RW or DVD-ROM drive
4.
PCI Expansion Card Slot
5.
Front USB Ports (2)
5.
PCI Expansion Card Slot
6.
Non-Hot Plug Non Redundant fans (4 fans)
6.
UID LED Button
7.
Air Baffle
7.
(Optional) LO100i 10/100 Mbps LAN port for IPMI
management (RJ-45)
8.
PCI Cage
9.
System Board
8.
LAN Port
9.
LAN Port
10.
2 Rear USB 2.0 Ports
11.
VGA Port
12.
Serial Port
What's New
What's NewWhat's New
What's New
Support for HP 900GB 6G SAS 10K SFF (2.5-inch) Enterprise 3yr Warranty Hard Drive
QuickSpecs
HP ProLiant DL180 Generation 6 (G6)
HP ProLiant DL180 Generation 6 (G6)HP ProLiant DL180 Generation 6 (G6)
HP ProLiant DL180 Generation 6 (G6)
Overview
DA - 13248 North America — Version 34 — May 9, 2011
Page 1
Page view 0
1 2 3 4 5 6 ... 59 60

Summary of Contents

Page 1 - QuickSpecs

The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellenceand 2U density for

Page 2

WarrantyWarrantyWarrantyWarrantyThis product is covered by a global limited warranty and supported by HP Services and a worldwidenetwork of HP Authori

Page 3

HP Insight ControlHP Insight ControlHP Insight ControlHP Insight Controlmanagement softwaremanagement softwaremanagement softwaremanagement softwareHP

Page 4

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster PlatformsHP Cluster Platforms are specifica

Page 5

Service and SupportService and SupportService and SupportService and SupportHP Technology Services for Industry Standard Servers and BladeSystemHP Tec

Page 6

Standard Care PackageStandard Care PackageStandard Care PackageStandard Care PackagePackage that maintains high level of server availabilityPackage th

Page 7

Four Drive Serial ATA (SATA) ModelsFour Drive Serial ATA (SATA) ModelsFour Drive Serial ATA (SATA) ModelsFour Drive Serial ATA (SATA) ModelsNOTE:NOTE:

Page 8

WarrantyWarrantyWarrantyWarrantyServer Warranty includes 3-Years Next Business Day Parts replacement, 0-Years Labor, 0-Years Onsite supportEight Drive

Page 9

Twelve Drive Serial ATA (SATA) ModelsTwelve Drive Serial ATA (SATA) ModelsTwelve Drive Serial ATA (SATA) ModelsTwelve Drive Serial ATA (SATA) ModelsNO

Page 10

P410/256 BBWC 25 SFFP410/256 BBWC 25 SFFP410/256 BBWC 25 SFFP410/256 BBWC 25 SFF750W PS Server750W PS Server750W PS Server750W PS Server590640-001Cach

Page 11

The ProLiant Smart Buy program offers a collection of promotional server and option products that are configured with SMB in mind,offered at discounte

Page 12

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - FactoryInteg

Page 13

S-BUY DL180G6 E5540S-BUY DL180G6 E5540S-BUY DL180G6 E5540S-BUY DL180G6 E55408GB 8LFF8GB 8LFF8GB 8LFF8GB 8LFF532078-005Processor(s)Processor(s)Processo

Page 14

S-BUY DL180G6 X5660S-BUY DL180G6 X5660S-BUY DL180G6 X5660S-BUY DL180G6 X566024GB 12LFF24GB 12LFF24GB 12LFF24GB 12LFF605664-005Processor(s)Processor(s)

Page 15

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Page 16

Step 2: Choose Required Options (only one of the following from each list unless otherwiseStep 2: Choose Required Options (only one of the following f

Page 17

HP MemoryHP MemoryHP MemoryHP MemoryRegistered RDIMMsRegistered RDIMMsRegistered RDIMMsRegistered RDIMMsHP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-13

Page 18

HP Power SuppliesHP Power SuppliesHP Power SuppliesHP Power SuppliesNOTE:NOTE:NOTE:NOTE: Many HP ProLiant Servers now offer new power options, includi

Page 19

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Page 20

HP DL180 G6 Intel® Xeon® E5603 (1.60GHz/4-core/4MB/80W) Processor Kit636207-B21HP DL180 G6 Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W) Processor Kit5

Page 21

HP S-Buy 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9Memory Kit500662-S21HP 16GB (1x16GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Regis

Page 22

HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty HardDrive507127-B21HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterpris

Page 23

Intel® Xeon® E5503 (2.0GHz/2-core/4MB/80W, DDR3-800) ProcessorNOTE:NOTE:NOTE:NOTE: Available through Configure To Order only. See Factory Integration

Page 24

HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive S-Buy454146-S21HP 500GB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Ha

Page 25

HP InfiniBandHP InfiniBandHP InfiniBandHP InfiniBandQLogic IB 4X QDR PCI-e G2 Dual-port HC583211-B21HP IB 4X QDR CX-2 PCI-e G2 Dual Port HCA592520-B21

Page 26

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Page 27

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster Management UtilityHP Cluster Management Uti

Page 28

HP Security - TPMHP Security - TPMHP Security - TPMHP Security - TPMHP Trusted Platform Module Option Kit488069-B21NOTE:NOTE:NOTE:NOTE: The TPM (Trust

Page 29

HP 512MB P-Series Battery Backed Write Cache UpgradeNOTE:NOTE:NOTE:NOTE: Supported on HP Smart Array P410 Controller and HP Smart Array P411Controller

Page 30

HP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoverySoftwareSoftwareSoftwareSoftwareData Protector Express

Page 31

HP Disk BackupHP Disk BackupHP Disk BackupHP Disk BackupNOTE:NOTE:NOTE:NOTE: For the complete range of StorageWorks D2D Backup Systems see:http://www.

Page 32

HP StorageWorks U320e SCSI Dual Channel Host Bus AdapterNOTE:NOTE:NOTE:NOTE: Recommended for MSL SCSI Tape Library connect.AH627AStorageWorks Converge

Page 33

HP Power DistributionHP Power DistributionHP Power DistributionHP Power DistributionUnitsUnitsUnitsUnitsMonitored PDUsMonitored PDUsMonitored PDUsMoni

Page 34

Expansion SlotsExpansion SlotsExpansion SlotsExpansion SlotsSlot NumberSlot NumberSlot NumberSlot NumberBus SpeedBus SpeedBus SpeedBus SpeedBus Number

Page 35

doors, you must allow 830 square inches (5,350 sq cm) of hole evenlydistributed from top to bottom to permit adequate airflow (equivalent to therequir

Page 36

HP USB and SD OptionsHP USB and SD OptionsHP USB and SD OptionsHP USB and SD OptionsHP USB-PS/2 MouseDC369AHP USB 04 Standard KeyboardDT528A#ABAHP Car

Page 37

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".HP ProLiant DL180 G6HP ProLiant DL180 G6HP Pro

Page 38

DIMM Type ->Registered DIMMS (RDIMMs)Registered DIMMS (RDIMMs)Registered DIMMS (RDIMMs)Registered DIMMS (RDIMMs)Unbuffered with ECC DIMMsUnbuffered

Page 39

12 DIMM SLOTS (6 per CPU node)12 DIMM SLOTS (6 per CPU node)12 DIMM SLOTS (6 per CPU node)12 DIMM SLOTS (6 per CPU node) CPU1CPU1CPU1CPU1 CPU2CPU2CPU2

Page 40

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11D: 16GB DIMM1D: emptyChnl 12A: 16GB DIMM2A: empty Ch

Page 41

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11D: 4GB DIMM1D: 4GB DIMMChnl 12A: 4GB DIMM2A: 4GB DIMM

Page 42

HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 LowPower Memory Kit500660-B21HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Regi

Page 43

8 Drive Cage with DVD-Drive bay 1-8Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays9DVD-ROM, DVD RW12 Drive Cage 1-12Twelve 3.5" Hot Plug SA

Page 44

HP Smart Array P410/1G FBWC ControllerHP Smart Array P812/1G FBWC ControllerHP Smart Array P800/512 BBWC ControllerHP Smart Array Hot Plug Advance Pac

Page 45

(P/N: 516471-B21) is required to enable RAID 6, 6+0NOTE:NOTE:NOTE:NOTE: To achieve highest possible stated transfer rate please make sure the firmware

Page 46

HP Smart Array P410/512 MB BBWC ControllerHP Smart Array P410/512 MB FBWC ControllerHP Smart Array P410/1G FBWC ControllerHP Smart Array P812/1G FBWC

Page 47

HP Smart Array P812/1G FBWC ControllerHP Smart Array P800/512 BBWC ControllerUp to 14 with 12drive cage +Rear Drive Cage1-14HP Smart Array P212/256 MB

Page 48

External StorageExternal StorageExternal StorageExternal Storage QuantityQuantityQuantityQuantitySupportedSupportedSupportedSupportedPositionPositionP

Page 49

HP StorageWorks SASHP StorageWorks SASHP StorageWorks SASHP StorageWorks SASTape DrivesTape DrivesTape DrivesTape DrivesDAT 160DAT 320LTO-2 Ultrium 44

Page 50

HP StorageWorks D2DHP StorageWorks D2DHP StorageWorks D2DHP StorageWorks D2DBackup Systems, iSCSIBackup Systems, iSCSIBackup Systems, iSCSIBackup Syst

Page 51

HP 460W Common Slot Gold Hot Plug Power Supply KitHP 460W Common Slot Gold Hot Plug Power Supply KitHP 460W Common Slot Gold Hot Plug Power Supply Kit

Page 52

HP 460W Common Slot Platinum Hot Plug Power Supply KitHP 460W Common Slot Platinum Hot Plug Power Supply KitHP 460W Common Slot Platinum Hot Plug Powe

Page 53

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions (H x W x D)(with bezel)3.45" x 17.64" x 28.23" in

Page 54

installed.System performance may be reduced if operatingwith a fan fault or above 30°C (86°F).Non-operatingNon-operatingNon-operatingNon-operating-30°

Page 55

HP 160GB 3G SATAHP 160GB 3G SATAHP 160GB 3G SATAHP 160GB 3G SATA7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5-inch)7.2K rpm LFF (3.5

Page 56

Industry StandardIndustry StandardIndustry StandardIndustry StandardComplianceComplianceComplianceComplianceACPI V2.0 CompliantPCI 2.2 CompliantPXE Su

Page 57

Smart Array P410/410iSmart Array P410/410iSmart Array P410/410iSmart Array P410/410iControllerControllerControllerControllerDisk Drive and EnclosureDi

Page 58

System FansSystem FansSystem FansSystem Fans4 system fans ship standard; Non-hot plug, Non-redundantNOTE:NOTE:NOTE:NOTE: Redundant fan kit (P/N 516009

Page 59

agents, providers, and a SmartStart 'like' deployment CD called Easy Set-upwhich greatly simplifies server set-up. Additionally the DL100 an

Page 60

AutoRunArray Configuration Utility (ACU) has been combined with ArrayDiagnostics Utility (ADU) to offer both configuration of arraycontrollers and sto

Comments to this Manuals

No comments