HP DL380z Generation8 (Gen8) Virtual
Workstation
XXXX-XXXXENW — Worldwide — June, 2014
Dimensions (H x W x
D)
(with bezel)
SFF Drives: 3.44 x 17.54 x 27.50 in (8.73 x 44.55 x 69.85 cm)
Minimum
(one SFF hard drive,
power supply, and
processor installed,
ODD not installed)
Input Requirements
(per power supply)
100 to 120 VAC
200 to 240 VAC
For 1200 W Power Supply:
10 A (at 100 VAC),
4.9 A (at 200 VAC)
For 1200 W Power Supply:
930 W (at 100 VAC),
1348 W (at 200 VAC)
For 1200 W Power Supply:
3530 BTU/hr (at 100 VAC),
4600 BTU/hr (at 200 VAC)
Power Supply Output
(per power supply)
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
-30° to 60°C (-22° to 140°F). Maximum rate
of change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
10% to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature,
non-condensing.
5% to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.
3048 m (10,000 ft). This value may be limited
by the type and number of options installed.
Comments to this Manuals