System Unit
Dimensions (H x W x
D)
(with bezel)
SFF Drives: 3.44 x 17.54 x 27.50 in (8.73 x 44.55 x 69.85 cm)
Weight (approximate)
Maximum
61.00 lb (27.66 kg)
Minimum
(one SFF hard drive,
power supply, and
processor installed,
ODD not installed)
41.0 lb (18.59 kg)
Input Requirements
(per power supply)
Rated Line Voltage
100 to 120 VAC
200 to 240 VAC
Rated Input Current
For 1200 W Power Supply:
10 A (at 100 VAC),
4.9 A (at 200 VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
For 1200 W Power Supply:
930 W (at 100 VAC),
1348 W (at 200 VAC)
BTU Rating
Maximum
For 1200 W Power Supply:
3530 BTU/hr (at 100 VAC),
4600 BTU/hr (at 200 VAC)
Power Supply Output
(per power supply)
Rated Steady-State
Power
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
Maximum Peak Power
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate
of change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature,
non-condensing.
Non-operating
5% to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.
Altitude
Operating
3048 m (10,000 ft). This value may be limited
by the type and number of options installed.