1.
2.
3.
4.
Make sure that the system power is off and that the power cord is
unplugged.
Remove the system cover.
If connected, disconnect the system from the network. If the system uses
a network eonneetor, unplug it from the network walloutlet. If the sys-
tem uses BNC
connectors to eonneet to the network. unDlue them from
the rear of thes tern unit. This opens the loop in the n~tw&k.To com-
plete the loop w ile ou are servicm the system,use a barrel type BNC
‘{ +
connector between t e IN and OU connectors.
Plug in the power cord and ~wer on the system.
Do not unplug the J(IO4
eonncctor from the CPU board. Measure the volts es through the top of
fthe connector. Use the voltmeter to test for the vo tages on the
J(K)4
eonneetor as listed in Table 4-1.
Voltage
(V dc)
+5
Ground
+12
-12
+12
+9
+5
+12
Ground
T&le 4-1. Power Supply Voltagesand Tolerances
(Model 400L 4251, and 400dl)
Tolerance at
JfJ04 Connector
4.85 to 5.25 V dc
11.4to 12.6V dc
-11.28 to -12.72 V dc
11.4 to 12.6 V dc
8.7 to 9.3
Toleranee at P2
and P3 Connector
4.85 to 5.25 V dc
11.4to 12.6V dc
J004p~nonnoector
.
1,3, and 9
14, 16, 18,and 20
7
6
4
differential betwee
Pins 17 and 19
P2 and P3
Connector Pin No,
4
1
2 and 3
Wme
Color
Red
Black
Violet
Green
Brown
Orangt
Yellow
Wire
Color
Red
Violet
Black
Troubleshooting
4-17