HP Moonshot 1500 Chassis Setup and Installation Guide Abstract This document contains setup, installation, and configuration information for the HP
Identifying components and LEDs 10 Chassis front panel components Item Description 1 Bezel ear 2 Backplane assembly release lever 3 Serial label
Identifying components and LEDs 11 Item Description LED Status 4 Cartridge health LEDs Green = Normal operation Amber = Standby mode Flashing Amb
Identifying components and LEDs 12 Fan bay numbering Fan LED Status Description Off The fan is working or the power is off. Solid amber The fan
Identifying components and LEDs 13 Power supply LED Status Description Off • No AC power to power supply units. Check the AC power co
Identifying components and LEDs 14 Item Component Description 1 Serial console port For management 2 SFP+ ports X1–X6 1Gb or 10Gb Ethernet
Identifying components and LEDs 15 Moonshot-4QSFP+ Uplink Module components Item Component Description 1 Serial console port For management
Identifying components and LEDs 16 Item Description Status 1 Uplink module UID LED/button Solid blue = Switch module ID is selected. Flashing blu
Identifying components and LEDs 17 HP Moonshot 1500 Chassis Management module LEDs and buttons Item Description Label 1 iLO CM management port
Identifying components and LEDs 18 Cartridge slot and switch module bay identification The chassis provides 45 cartridge slots (1-45) and two switch
Identifying components and LEDs 19 Cartridge LEDs and buttons Item Description Status 1 Cartridge power LED/button Green = Normal operation A
© Copyright 2013, 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr
Identifying components and LEDs 20 Switch module button, sensor, and LEDs Item Description Status 1 Switch module power LED Green = Normal opera
Installing the chassis 21 Installing the chassis Installation overview To set up and install the chassis: 1. Unpack the Moonshot System ("Unpa
Installing the chassis 22 WARNING: The chassis is very heavy. To reduce the risk of personal injury or damage to the equipment, do the following:
Installing the chassis 23 1. Fully extend the rails by pressing the push tabs and extending the rails until the rails click two times. WARNING:
Installing the chassis 24 2. Install the chassis into the J-slot on the rails, and then pull it forward. 3. Push in the release lever, and the
Installing the chassis 25 Installing the blanking panel If the rack rail adapter kit is not installed on the rack, always install the blanking p
Installing the chassis 26 2. Attach a cage nut to each side of the rack. 3. Align the blanking panel. 4. Secure the blanking panel to the rack.
Installing the chassis 27 Maintenance and Service Guide or cartridge-specific user and maintenance guides in the HP Moonshot Information Library (ht
Installing the chassis 28 To install the component: Install the power supply into the device bay, and then press firmly until the power supply is se
Installing the chassis 29 Installing the cartridge To install the component: 1. Prepare the cartridge. 2. Align and install the cartridge into th
Contents 3 Contents Planning the installation ...
Installing the chassis 30 • Always install the switch module and the uplink module in corresponding bays. Both components must be installed for nor
Installing the chassis 31 Production network mapping The first network interface discovered by the operating system routes traffic through switch A
Installing the chassis 32 Management network mapping All traffic from the service port management interface is routed through the iLO CM management
Installing the chassis 33 CAUTION: For proper cooling, be sure every switch module bay and uplink module bay has either a blank or a module ins
Installing the chassis 34 To install the component: 1. Locate the switch module slot, and then remove the blank. 2. Prepare the switch module for
Installing the chassis 35 3. Align and install the switch module into the chassis. 4. Do one of the following: o If the uplink module is already
Cabling the HP Moonshot System 36 Cabling the HP Moonshot System Cabling overview WARNING: To reduce the risk of electric shock or injury due to
Cabling the HP Moonshot System 37 Moonshot iLO CM firmware SSH sessions and switch SSH sessions share connectivity through the iLO CM management por
Cabling the HP Moonshot System 38 • Moonshot 4QSFP+ Uplink Module Connecting power cables and applying power to the chassis 1. Connect the power
Configuring the HP Moonshot System 39 Configuring the HP Moonshot System Chassis configuration overview To configure the HP Moonshot System, complet
Contents 4 Installing network components ...
Configuring the HP Moonshot System 40 Log in to the iLO CM firmware After the terminal session is started, log in as administrator at the login prom
Configuring the HP Moonshot System 41 Always use the recommended firmware version for all Moonshot System components. For more information on recomm
Configuring the HP Moonshot System 42 For detailed configuration information, see the Switch Administrator's Guide and Switch CLI Guide in the
Configuring the HP Moonshot System 43 enable password {password} Updating the switch firmware using the switch console Use TFTP, SFTP, or SCP to up
Configuring the HP Moonshot System 44 Power capping The HP Moonshot System provides a power capping feature that operates at the chassis level. The
Configuring the HP Moonshot System 45 Example: hpiLO-> show chassis power Chassis: #------- Power in use: 170 Watts Power Capacity: 1818
Troubleshooting 46 Troubleshooting Troubleshooting resources The HP Moonshot System Troubleshooting Guide provides procedures for resolving common p
Regulatory information 47 Regulatory information Safety and regulatory compliance For safety, environmental, and regulatory information, see Safety
Regulatory information 48 Valid date formats include the following: • YWW, where Y indicates the year counting from within each new decade, with 20
Electrostatic discharge 49 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions yo
Planning the installation 5 Planning the installation Safety and regulatory compliance For safety, environmental, and regulatory information, see Sa
Specifications 50 Specifications Chassis environmental specifications Specification Value Temperature range* — Operating 10°C to 35°C (50°F to 95°
Support and other resources 51 Support and other resources Before you contact HP Be sure to have the following information available before you call
Support and other resources 52 NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP require
Support and other resources 53 Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella so
Support and other resources 54 CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert. Für bestimmte
Support and other resources 55 Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su
Support and other resources 56 Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pel
Support and other resources 57
Support and other resources 58
Acronyms and abbreviations 59 Acronyms and abbreviations CM chassis management CPLD complex programmable logic device DHCP Dynamic Host Configurat
Planning the installation 6 covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992 (code for Protection of Electronic Computer/
Acronyms and abbreviations 60 TFTP Trivial File Transfer Protocol UPS uninterruptible power system
Documentation feedback 61 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentat
Index 62 A access panel 9 accessing the CLI 42 activity LED 10 administrator password 40 airflow requirements 7 authorized reseller 51 B
Index 63 firmware 40, 41, 43 firmware upgrade utility, troubleshooting 46 front panel components 10, 19 G grounding methods 49 grounding req
Index 64 power supply LEDs 13 power supply, installing 27 power up procedure 38 powering up 38 Power-on events 38 preparation procedures
Planning the installation 7 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The rack is bolted to the
Planning the installation 8 HP rack products draw cool air in through the front and expel warm air through the rear of the enclosure. Therefore, the
Identifying components and LEDs 9 Identifying components and LEDs HP Moonshot System components Item Description 1 HP Moonshot 1500 Chassis 2
Comments to this Manuals