HP StorageWorks
XP10000 Disk Array Owner's Guide
Part number: AE102-96013
Seventh edition: March 2008
Page view 0
1 2 3 4 5 6 ... 53 54

Summary of Contents

Page 1 - HP StorageWorks

HP StorageWorksXP10000 Disk Array Owner's GuidePart number: AE102-96013Seventh edition: March 2008

Page 2

• Detailed questionsFor continuous quality improvement, calls may be recorded or monitored.Customer self repairHP customer self repair (CSR) programs

Page 3 - Contents

1 Overview of the HP XP10000 Disk ArrayThis disk array is part of the HP StorageWorks XP Disk Array series of high-performance RAID-capabledisk array

Page 4

the appropriate maintenance activity, without interruption to applications or hosts. For more information,see “HP StorageWorks Continuous Track XP” on

Page 5

2. Controller, power supplies, control panel, SVP, diskadapters1. Front of the open HP XP10000 disk array4. R1 disk chassis, containing up to 60 disk

Page 6

2. Add a second rack with one 60-disk chassis (R2, #7 in Figure 1), providing a total of up to 180drives.3. Add a second 60-disk chassis (R3, #8 in Fi

Page 7 - About this guide

• HP RAID Manager Library software• Site preparation services• Installation and configuration services• Proactive monitoring and support• Reactive har

Page 8

SpecificationFeature120 in one rack, 240 in two racksMaximum hard disk drives16Maximum spare disk drives59Maximum parity groups/array69.2 TBMaximum di

Page 9 - HP technical support

• Nonstop• VMware• z/OS• MainframeFor the latest information on supported operating systems and versions, contact your HP supportrepresentative or vis

Page 10 - Documentation feedback

• Simplify disaster recovery• Improve data securityThe following topics summarize the types of available software. To learn about specific XP software

Page 11 - Continuous data availability

• HP StorageWorks XP Continuous Access Journal Software• HP StorageWorks XP RAID Manager• HP StorageWorks XP Replication Monitor Software• HP StorageW

Page 12 - Scalability

Legal and notice information© Copyright 2005, 2008 Hewlett-Packard Development Company, L.P., all rights reserved.Confidential computer software. Vali

Page 13 - Adding storage

Overview of the HP XP10000 Disk Array20

Page 14 - HP XP10000 product contents

2 HP XP10000 hardware componentsThere are no single points of failure in HP XP10000 disk arrays. Redundant logic assemblies,controllers, disk drives,

Page 15 - HP XP10000 supported features

Figure 2 HP XP10000 control panel componentsTable 3 HP XP10000 control panel componentsDescriptionIndicatorLabelItemDuring normal operation, this LED

Page 16 - Supported operating systems

DescriptionIndicatorLabelItemDuring normal operation, this LED should be off.ON: A service information message (SIM) hasbeen issued from either storag

Page 17 - HP XP10000 Software

DescriptionIndicatorLabelItemDuring normal operation, this LED should be on.ON: The disk array is plugged in and receivingpower from the primary AC ou

Page 18 - Storage management software

The disk array must contain at least one spare disk drive and can contain up to 16. Any of the sparedisk drives can back up any other disk drive of eq

Page 19 - Mainframe software

1. Command View XP Advanced Edition server2. Ethernet LAN connection3. XP disk arrayFigure 4 Optional HP StorageWorks XP Command View Advanced Edition

Page 20

3 HP XP10000 operationsDuring normal operations, the disk array does not require intervention and you should not attempt toopen the disk array cabinet

Page 21 - Control panel

CAUTION:Do not perform any procedures not described in this guide. If you have any questions or concerns,contact your HP support representative.WARNIN

Page 22 - DescriptionIndicatorLabelItem

Emergency power offThe system does not have an emergency power off switch. In an emergency when it is crucial to poweroff the system immediately for s

Page 23

ContentsAbout this guide ... 7Intended audience ...

Page 24 - Disk drives

Manual restart after power is restoredCAUTION:After power is restored to your site and before restoring power to the system, HP recommends that youhav

Page 25 - Optional management server

PS-ON turns green.MESSAGE LED may turn amber if the system is not configured for remote support, signifying a SIMwas generated because the system lost

Page 26 - 3. XP disk array

Non-condensing relative humidity (RH)Humidity range type27 degrees C (81 F)Non-operating maximum wet bulb temperature29 degrees C (84 F)Shipping and s

Page 27 - 3 HP XP10000 operations

4 HP XP10000 TroubleshootingService information messagesThe system generates service information messages (SIMs) to identify normal operations, servic

Page 28 - Powering down the disk array

DescriptionItemIf the system is set up for remote support, HP XP Continuous Track reports the SIMs to STC througha dedicated dialup connection.SIMs ar

Page 29 - Planned power off

5 Regulatory statementsFCC EMC statement (USA)This equipment has been tested and found to comply with the limits for a Class A digital device,pursuant

Page 30 - HP XP10000 operations30

VCCI EMC statement (Japan)BSMI EMC statement (Taiwan)RRL EMC statement (Korea)Harmonics conformance (Japan)German noise declarationXP10000: Schalldruc

Page 31 - Operating specifications

board, and on the 16-port Fibre Channel Adapter board and 16-port FICON board for connectionto a fibre communications network.In the USA, the OLM is c

Page 32 - AC line voltage requirements

DutchEnglishEstonianRegulatory statements38

Page 33 - 4 HP XP10000 Troubleshooting

FinnishFrenchGermanXP10000 Disk Array Owner's Guide 39

Page 34 - DescriptionItem

Optional management server ... 253 HP XP10000 operat

Page 35 - 5 Regulatory statements

GreekHungarianItalianRegulatory statements40

Page 36 - Regulatory statements36

LatvianLithuanianPolishXP10000 Disk Array Owner's Guide 41

Page 37 - European WEEE statements

PortugueseSlovakSlovenianRegulatory statements42

Page 38 - Estonian

SpanishSwedishXP10000 Disk Array Owner's Guide 43

Page 39

Regulatory statements44

Page 40 - Hungarian

GlossaryACP Array control processor. On some XP models, such as the XP12000, the ACPhandles the passing of data between the cache and the physical dri

Page 41 - Lithuanian

channel processor(CHP)The processors located on the channel adapter (CHA). Synonymous with CHIP.command device A volume on the disk array that accepts

Page 42 - Slovenian

FC-AL Fibre Channel arbitrated loop.FCP Fibre Channel Protocol.fence level A level for selecting rejection of a write I/O request from the host accord

Page 43

mirroringconsistencyThe consistency (usability) of data in a volume (for example, S-VOL).mm Millimeters.MR Magnetoresistive.ms, msec Milliseconds.mutu

Page 44 - Regulatory statements44

RAID group See “array group.”RAID level A RAID Level is one of the ways that disk drives are grouped together to improveperformance, data availability

Page 45 - Glossary

FiguresHP XP10000 Disk Array configuration ... 131HP XP10000 control panel compone

Page 47

IndexAAC power, 32array management, 17audience, 7automatic restart, 30Bbatteries, backup, 25, 29Ccablesmechanical vibration, 32cache battery backup, 2

Page 48 - Glossary48

Hhardwarecontrol panel, 21disk array frame, 24disk control frame, 21disk drives, 24features, 14management server, 25normal operations, 27physical comp

Page 49

Wwarninghazard, 27rack stability, 9websitescustomer self repair, 10HP, 10HP Subscriber's Choice for Business, 10product manuals, 7wet bulb temper

Page 51

TablesDocument conventions ... 71HP XP10000 Disk Array spe

Page 52

About this guideThis guide provides information about owning and operating the HP StorageWorks XP10000 DiskArray.Unless otherwise noted, the term disk

Page 53

ElementConvention• Keys that are pressed• Text typed into a GUI element, such as abox• GUI elements that are clicked or selected,such as menu and list

Page 54

Conventions for storage capacity valuesUse the following values to calculate physical storage capacity (hard disk drives) for HP XP storagesystems:• 1

Comments to this Manuals

No comments