HP 3PAR StoreServ 10000 Base Configurations
Configurations supporting single phase power
HP 3PAR StoreServ 10400 16GB Control/32GB Data Cache NEMA Rack Config Base
QR584C
HP 3PAR StoreServ 10400 16GB Control/32GB Data Cache IEC Rack Config Base
QR632C
HP 3PAR StoreServ 10400 16GB Control/32GB Data Cache Rackmount Config Base
QR633C
HP 3PAR StoreServ 10800 32GB Control/64GB Data Cache NEMA Rack Config Base
QR585C
HP 3PAR StoreServ 10800 32GB Control/64GB Data Cache IEC Rack Config Base
QR637C
A minimum of one (1) configuration base must be ordered
The base configuration for NEMA/IEC includes two Controller Nodes, one 2-meter
Cabinet, service processor
The Rackmount Configuration Base (QR633C) includes two Controller Nodes,
rackmount kit (for backplane, controllers and service processor), service processor. A
rackmount kit must be ordered separately for each drive chassis (see Drive section
below). These rackmount kits are strictly for new installations into non-HP 3PAR
racks.
The 10400 base configuration includes total cache: 32GB control / 64GB data
The 10800 base configuration includes total cache: 64GB control / 128GB data
The base configuration and node configurations, shown in the section below, have
built-in Gigabit Ethernet ports for management and Remote Copy over IP
The base configurations do not include adapters (beyond embedded ports), drive
chassis, drives, cables or expansion cabinets. These are to be ordered separately
NEMA stands for the National Electrical Manufacturers Association. IEC stands for the
International Electrotechnical Commission
With respect to HP 3PAR StoreServ 10000, NEMA (National Electrical
Manufacturers Association) and IEC (International Electrotechnical Commission)
refer to the plug types used. Generally, NEMA plugs are used in North America
and IEC plugs are used everywhere else. There are exceptions, e.g., NEMA plugs
are used in Japan.
The NEMA connector plug type used on the HP 3PAR StoreServ 10000 NEMA is
the L6-30P with 1+1 redundant. The NEMA receptacles used on the 10000
NEMA are the L6-30R with 1+1 redundant
The IEC connector plug type used on the HP 3PAR StoreServ 10000 IEC is the IEC
60309, blue 30/32A, 2P+E with 1+1 redundant. The IEC receptacles used on the
10000 IEC are the IEC 60309, blue 30/32A, 2P+E with 1+1 redundant
Configurations supporting three phase power
HP 3PAR StoreServ 10400 16GB Control/32GB Data Cache Rack Configuration Base
QW978A
HP 3PAR StoreServ 10400 16GB Control/32GB Data Cache Rackmount Config Base
QR633C
HP 3PAR StoreServ 10800 32GB Control/64GB Data Cache Rack Configuration Base
QW979A
A minimum of one (1) configuration base must be ordered
The base configuration includes two Controller Nodes, one 2-meter Cabinet, service
processor
The Rackmount Configuration Base (QR633C) includes two Controller Nodes,
rackmount kit (for backplane, controllers and service processor), service processor. A
rackmount kit must be ordered separately for each drive chassis (see Drive section
below). These rackmount kits are strictly for new installations into non-HP 3PAR
racks.
The 10400 base configuration includes total cache: 32GB control / 64GB data
QuickSpecs
HP 3PAR StoreServ 10000 Storage
Configuration
DA - 14103 Worldwide — Version 15 — June 10, 2013
Page 10