HP 28655A Datasheet

Browse online or download Datasheet for Interface cards/adapters HP 28655A. HP Single-ended SCSI-2/Centronics host adapter board User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Parallel

HP 28642A HP-PB SCSI HP 28655A HP-PB SCSI/ Parallel

Page 2 - 5960-3126 El091

1 Installing the HP 28642A/28655A Adapter

Page 3 - Safety Considerations

lnstalllng the HP 28642A/28655A Adapter This chapter contains installation instructions for the HP 28642A/28655A HP-PB SCSI/Parallel adapter card.

Page 4 - Installation and S&vice

1. Prepare to Install the Adapter Card Before installing the SCSI/parallel adapter card, perform the following: 1. Observe antistatic precautio

Page 5

Record Adapter Card Identification Information Should your card require service, its part number and date code may be needed by HP service perso

Page 6

Note You should have all of your system and peripheral device manuals available for refirence. There may be special system or device dependent requir

Page 7 - In This Book

2. Shut Down the System and SwZtch Off the Computer 1. Before installing the card, ensure that the operating system is shut down. Consult you

Page 8 - Table of Contents

3. Check the Card’s Hardware Configuration Hardware settings for the SCSI/parallel adapter apply to the SCSI port only. There are no hardware se

Page 9

Set the Desired Parity-Checking CapabUity AU devices on a SCSI bus must have the same parity-checking capability. If any device on the SCSI bus

Page 10 - HP 28642A/28655A Adapter

Set the SCSI Bus Address There may be up to eight devices (which includes the SCSI adapter) connected to a SCSI bus. Each device must have a unique

Page 11

Verify that Resistor Packs are Properly Installed A SCSI bus has two ends between which SCSL devices are attached. Each end of a SCSI bus mus

Page 13

4. Install and Connect the Card The HP-PB cardcage accommodates two sixes of cards: single-high (Eurocard standard 3U) or double-high (6U). T

Page 14

m Authorized or recommended slots for the SCSI/parallel adapter. - The SCSI/parallel adapter is a standard HP-PB card. Typically, it can be inst

Page 15

n Computer hardware limitations for l/O cards, if any. The HP-UX and MPE XL operating systems support the use of this card. However, the particula

Page 16

Prepare the Slot For Use To prepare a slot, you must first remove the metal slot cover. Then, if a plastic frl!er card is installed in the slot,

Page 17

Removing Filler Cards A plastic “filIer” card is normally installed when a slot is not in use. In some systems, the filler card helps to channel ai

Page 18 - Set the SCSI Bus Address

3. Press the slot divider until its retention clips clamp onto the locator bracket as illustrated in figure 1-9. Figure 1-9. Slot Divider Mat

Page 19 - Termination Resistors

Insert the Card into the Slot To install the adapter into its slot, proceed as follows: 1. Inspect the %-pin connector at the back of the slot o

Page 20 - Select an Appropriate Slot

Attach the Card Cables Figure l-10 shows a typical installation with both the SCSI port and parallel port cables attached (the use of the parall

Page 21 - HP-Pa Standard Power

Connect Your Peripheral Device(s) You can connect SCSI devices (single-ended devices only) to the SCSI port, and a parallel communication device to

Page 22 - Record the Slot Number

Set switches or jumpers on your device(s) as appropriate. Be sure each SCSI device has a unique SCSI address. For optimum noise immunity, any device

Page 23 - Prepare the Slot For Use

@Hewlett-Packard Company, 1991. AI1 rights rcservcd, Hewlett-hckard Company makes M wsmmty of any kind with regard to this material, btcb~dittg. but

Page 24 - Bracket

CAUTION Only the two ends of a SCSI bus should be terminated. Excessive or improper termination may overload the termination power circuitry on the

Page 25

A SCSI Cable Length Example Table l-3 and figure 1-12 demonstrate how to calculate SCSI bus cable lengths for a typical installation. The SCSI 0.5

Page 26 - CAUTION

Connect Your Parallel Device, If Applicable Output-only parallel devices, such as common printers, can be connected to the parallel port. Figur

Page 27 - Attach the Card Cables

Pin 1 Pin 13 Pin 14 Pin 25 Figure 1-13. Parallel Port Pins Table 1-4. Signal Pin Assignments Pin Number Signal Name In/Out Pin Number Signal

Page 28

Pin25 ;. II :: :: :: :: 0 . % Pin 36 Fin 1 Pin 1 25Pin Connector, Host End B-Pin Connector, Peripheral End Figure 1-14. Parallel Cable Wirin

Page 29 - Terminate the SCSI Bus

Turn Power On to Peripherals, Then to the Computer Before turning power on, follow these steps: 1. Verify that a11 cables are connected and

Page 30

7. Set Up the Operating System Before you can use your devices, the SCSI/parallel adapter card and peripheral devices must be configured into the

Page 31 - HP Device #2

8. Verify Operation To verify card operation, observe the light indicators: n The yellow self-test LED should be off. n The green termination p

Page 33

Service Information This chapter provides the following service and reference information: m Field Replaceable Units 8 Troubleshooting Tools H R

Page 34 - Installing the Adapter

Installation and S&vice HP28642A HP-PB SCSI HP 28655A HP-PB SCSI/Parallel

Page 35

Field Replaceable Units Field replaceable units (F’FWs) are assemblies or components that are authorized for field replacement. Field replacement of

Page 36 - MPE XL Systems

Board Components The foIIowing board components are available for replacement (see figure 2-l for location): PROM (location U52): 28655-81001 Fuse

Page 37 - 8. Verify Operation

Troubleshooting Tools Troubleshooting tools are used to identify faulty FRUs. For this product, the following tools are described below B Self-Te

Page 38 - Service Information

Self-Test Failure LED The Self-Test Failure LED is yellow and will indicate card test failures when used by fhe host system. Card self-test code c

Page 39 - Service Information

SCSIPBA and CENTPBA Diagnostics Standard diagnostics, scsipba and centpba, are available for use by authorized service personnel. For more informa

Page 40 - Field Replaceable Units

Table 2-I. Troubleshooting Checklist (continued) Are the SCSI bus terminators correctly installed? Both ends of the SCSI bus require termination

Page 41 - Other FRUs

Removal/Replacement Instructions This section describes removal and replacement instructions for the following items: l The SCSI/parallel adapter n

Page 42 - Troubleshooting Tools

Removal/Replacement of the Card For card removal, follow the procedures below: 1. Before removing the card, ensure that the operating system is sh

Page 43 - TERMPWR LED

Removal/Replacement of Card Components Replaceable card components are socketed to facilitate their removal and replacement. PROM and Termlnation

Page 44 - Troubleshooting Checklist

To install replacement components, proceed as follows: 1. Identify the proper socket location for the replacement component. 2. Note the half-circ

Page 45

HP 28642A and HP 28655A at a Glance A- Extractor lever. B - Retaining (captive) screw. C - Self-Test Fail LED (yellow), normally off. D -

Page 46 - WARNING

Note An open fuse condition can be also be determined from the scsipba diagnostic. If another device on the SCSI bus provides termination power, the

Page 47

Reshipment Guidelines If any item of the product is to be returned to Hewlett-Packard for any reason, contact your HP Safes and Support Office to

Page 48

Technical Specifications Table 2-2 SCSI/Parallel Adapter Technical Specifications General Supported I HP 9bOO Series 600/800 HP-PB computers (HP

Page 49

Table 2-2. SCSI/Parallel Adapter Technical Specifications (continued) Voltage Current (Typical) Power ~tcal) Electrical +5 Vdc 0.75 A 3.75 w +

Page 50

Glossary adapter, adapter card An add-on computer interface card and circuitry that provides the physical connection and data translation between

Page 51 - Reshipment Guidelines

device In this manual, refers to the peripheral units that are attached to the SCSI/parallel adapter card. device adapter See adapter. differential

Page 52 - 1 (green)

host adapter See adapter. HP-PB Hewlett-Packard Precision Bus. The data, control, and addressing signal lines for input/output operation on Hewlett-

Page 53 - Environmental

loopback hood A special connector with signal lines configured to allow loopback testing of the adapter card. low-density connector In reference to t

Page 54 - Glossary

SCSI-2 Complies with the SCSI specilication X3.131 - 1990. SCSI-Z provides extensions and further standardization of SCSI-l. SCSI address The octal

Page 55

system administrator The person who manages or controls the configuration and operation of a computer system. terminator An assembly that contains a r

Page 56

Product Description The HP 2S642A/HP 2S655A HP-PB adapter is a computer interface card for use in HewIett-Packard computers that use the HP-PB (HP Pr

Page 57

Index A accessories...l-4 adapter configuration...l-7 connecting...1-11 exchange assembly..23 hardware address...&l3 HP-PB specifications...l-12 H

Page 58 - SCSI bus

C cable connecting to the card...l-18 paraliel...l-3, l-23,2.4 part number...l-3,1-S, l-21 SCSI...l-3,1-18,2-4 SCSI bus length...l-20,1-21 troublesh

Page 59

electrical specifications..216 electromagnetic specifications..2-16 environmental specifications..516 exchange assembly part number...2-3 F field repl

Page 60

L LEDs...2-6 troubleshooting...2-5 verifying card operation...l-28 light emitting diodes See LEDs loopback hood...2-4 MPE XL system...2-15 configur

Page 61 - 2 - Index

power during instailation/removai...l.6,1-19, l-26,2-10 symbol for standard power sIot...l-12 product contents...13 PROMS removaVreplacement..2-11 R

Page 62

slot divider..S-4,1-5 instaBiig...l-15 specifications...2-14 storing adapter cards...l-3 switch default settings&S hIcation...1.7 &ylrlbo~ sta

Page 63

Reorder No. or Manual Part No. 5960-3126 El091 Printed on Recycled Paper HEWLETT:,’ PACKARD I llllllll I lllll III lllll llll llllll Ill 11111 I

Page 64

In This Book This manual contains installation and service information for the: n HP 28642A HP-PB SCSI adapter for MPE XL systems, and I HP 28655A

Page 65

Table of Contents Chapter 1. Installing the HP 2s642Al28655A Adapter 1, Prepare to Install the Adapter Card ... 1-3 Observe

Page 66 - 5960-3126

Chapter 2. Service Information Field Replaceable Units ......... 2-3 Exchange Assembly ......... 2-3

Comments to this Manuals

No comments