Page view 13
HPTESTEVENT utility
The hptestevent utility allows an application to request, so that the HP Insight Management
WBEM Providers generate the Informational Test Indication with ProviderName “HP Test and
EventID 1, and the CPQ SNMP test trap with OID 1.3.6.1.4.1.232.11.2.8.1.0.11003.
The HP Insight Management WBEM Providers must be installed, enabled and running on the system
where this utility is executed. The WBEM Providers must be configured to send indications to the
listener. VMware SNMP traps must be enabled and configured to use WBEM indications as a
source for SNMP traps.
The Informational Test Indication and the CPQ Test SNMP trap will be sent to any listener configured
to receive indications from the system.
See the HP Insight Management WBEM Provider Datasheets for information on the test indication,
and the SNMP Data Migration Guide for information on the test SNMP trap on the BSC (Business
Support Center).
HPTESTEVENT command-line syntax
Use the following format at the command line:
hptestevent
There are no command options for the hptestevent utility.
HPTESTEVENT ESXCLI syntax
The hptestevent utility is supported by the ESXCLI utility.
To view the command usage options, run the following command:
# esxcli hptestevent
The following output is displayed:
Usage: esxcli hptestevent {cmd} [cmd options]
Available Commands:
execute execute the hptestevent command
To request a test indication and test SNMP trap to be generated, run the following command:
# esxcli hptestevent execute
The following output is displayed:
Request successful. Test event will be generated.
HPTESTEVENT return codes
This section provides description about the return code after running the command.
Table 8 hptestevent return codes
MeaningValue
Indicates success0
Request failed. No test event will be generated.1
Request failed, must be root. No test event will be generated.2
Request failed, couldn't determine if HP WBEM Providers are installed and running. No test
event will be generated.
3
Request failed, HP WBEM Providers are not installed and running. No test event will be
generated.