Page 1 - User Guide

HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide April 2005 (First Edition) Part Number 391001-001

Page 2 - Audience assumptions

10 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Rear panel components Item Description 1* PCI-X expansion slot 1, 64-bit/133-

Page 3 - Contents

100 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide POST problems flowchart Symptoms: • Server does not complete POST NOTE: The

Page 4

Troubleshooting 101 Item Refer to 7 • "Hardware problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation

Page 5

102 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide

Page 6

Troubleshooting 103 OS boot problems flowchart Symptoms: • Server does not boot a previously installed operating system • Server does not boot Sm

Page 7 - Front panel components

104 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item Refer to 8 • "Hardware problems" in the HP ProLiant Servers Trou

Page 9

106 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Server fault indications flowchart Symptoms: • Server boots, but a fault event

Page 10 - Rear panel components

Troubleshooting 107 Item Refer to 6 • "Hard drive problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentatio

Page 11 - Rear panel LEDs and buttons

108 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide

Page 12 - System board components

Troubleshooting 109 POST error messages and beep codes List of messages: Introduction to POST error messages...

Page 13 - System maintenance switch

Server component identification 11 * Depending on the model of the server, slot 1 or slot 2 will be pre-populated with a storage controller. If t

Page 15

111 Electrostatic discharge In this section Preventing electrostatic discharge ...

Page 16

112 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Grounding methods to prevent electrostatic discharge Several methods are used fo

Page 17

113 Regulatory compliance notices In this section Regulatory compliance identification numbers...

Page 18 - Internal USB connector

114 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Federal Communications Commission notice Part 15 of the Federal Communications C

Page 19 - SAS and SATA device numbers

Regulatory compliance notices 115 Class B equipment This equipment has been tested and found to comply with the limits for a Class B digital device

Page 20

116 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 772

Page 21 - Fan module locations

Regulatory compliance notices 117 European Union regulatory notice This product complies with the following EU Directives: • Low Voltage Directiv

Page 22

118 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Japanese notice BSMI notice

Page 23 - Server operations

Regulatory compliance notices 119 Korean notice A&B Class A equipment Class B equipment Laser compliance This product may be provided with

Page 24 - Powering down the server

12 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item Description Status 6 10/100/1000 NIC 1 activity Green = Activity exists. Fl

Page 25 - Server operations 25

120 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • Do not try to open the module enclosure. There are no user-serviceable compon

Page 26 - Installing the access panel

Regulatory compliance notices 121 Taiwan battery recycling notice The Taiwan EPA requires dry battery manufacturing or importing firms in accordanc

Page 28

123 Server specifications In this section Environmental specifications ...

Page 29 - Server setup

124 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Input requirement Specification Rated input voltage 100 VAC to 240 VAC Rated i

Page 30 - Rack planning resources

125 Technical support In this section Customer self repair...

Page 31 - Optimum environment

126 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • In Canada, call 1-800-263-5868. • In other locations, refer to the HP websit

Page 32 - Temperature requirements

127 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility ASR Automatic Server Recovery BBWC battery-backed write cac

Page 33 - Power requirements

128 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide iLO Integrated Lights-Out IML Integrated Management Log IPL initial program lo

Page 34 - Rack warnings

Acronyms and abbreviations 129 PCI Express peripheral component interconnect express PCI-X peripheral component interconnect extended PDU power

Page 35 - Server setup 35

Server component identification 13 Item Description 7 Optical device/multi-bay connector 8 Power supply connector 9 Power supply signal connec

Page 36 - Installing hardware options

130 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide SCSI small computer system interface SDRAM synchronous dynamic RAM SIM Systems

Page 37 - Server setup 37

Acronyms and abbreviations 131 VHDCI very high density cable interconnect WOL Wake-on LAN

Page 39 - Registering the server

133 Index A AC power supply 51 access panel 26 additional information 109, 125 ADU (Array Diagnostic Utility) 78 array, configuring 48

Page 40

134 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide G general diagnosis flowchart 95 grounding methods 112 grounding requirement

Page 41 - Processor option

Index 135 P PCI riser board 27 phone numbers 125 POST error messages 109 POST problems flowchart 100 power connectors, internal 12 power

Page 42

136 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide T Taiwan battery recycling notice 121 technical support 125 telephone number

Page 43

14 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide NMI switch The NMI switch allows administrators to perform a memory dump before p

Page 44 - Memory options

Server component identification 15 Item LED Description Status 3 DIMM 4B failure Amber = DIMM has failed. Off = DIMM is operating normally. 4

Page 45 - Single- and dual-rank DIMMs

16 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item LED Description Status 15 System diagnostic Refer to the HP Remote Lights

Page 46 - Installing DIMMs

Server component identification 17 System LED and color Internal Health LED color Status Processor failure, both sockets (Amber) Red Processor

Page 47 - Hard drive options

18 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide System LED and color Internal Health LED color Status Power supply signal interl

Page 48 - Removing a hard drive blank

Server component identification 19 SAS and SATA device numbers Identifying the status of a hard drive When a drive is configured as a part of a

Page 49

© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties f

Page 50

20 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide SAS and SATA hard drive LED combinations 1 - Fault/UID LED (amber/blue) 2 -

Page 51

Server component identification 21 Fan module locations Item Description 1 Power supply zone fan module 2 Processor zone fan module

Page 53 - Expansion board options

23 Server operations In this section Powering up the server ...

Page 54 - Expansion board

24 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Status Amber = One fan in this module has failed. Red = Multiple fans in this

Page 55

Server operations 25 Extending the server from the rack NOTE: If the optional cable management arm option is installed, you can extend the server

Page 56

26 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide b. Secure the server by tightening the thumbscrews. 6. Reconnect the peripheral

Page 57

Server operations 27 Removing PCI riser board assembly CAUTION: To prevent damage to the server or expansion boards, power down the server and r

Page 58

28 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Installing PCI riser board assembly CAUTION: To prevent damage to the server o

Page 59

29 Server setup In this section Optional installation services...

Page 60

3 Contents Server component identification 7 Front panel components...

Page 61 - Server cabling

30 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide – HP ProLiant Essentials (HP SIM and RDP) – VMWare • Integrated hardware and s

Page 62

Server setup 31 • The Rack Products Documentation CD enables you to view, search, and print documentation for HP and Compaq branded racks and ra

Page 63 - Configuration tools

32 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide CAUTION: Always use blanking panels to fill empty vertical spaces in the rack.

Page 64

Server setup 33 • Do not permit optional equipment to impede airflow around the server or to increase the internal rack temperature beyond the m

Page 65 - HP ROM-Based Setup Utility

34 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide For more information on the hot-plug power supply and calculators to determine se

Page 66

Server setup 35 • The leveling jacks are extended to the floor. • The full weight of the rack rests on the leveling jacks. • The stabilizing f

Page 67

36 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • Hardware options • Operating system or application software Installing hardw

Page 68 - Array Configuration Utility

Server setup 37 WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications c

Page 69

38 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide * Depending on the model of the server, slot 1 or slot 2 will be pre-populated w

Page 70 - Management tools

Server setup 39 Installing the operating system To operate properly, the server must have a supported operating system. For the latest informatio

Page 71 - ROMPaq utility

4 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Installing the server into the rack...

Page 73 - Erase Utility

41 Hardware options installation In this section Introduction ...

Page 74 - HP Systems Insight Manager

42 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide CAUTION: To prevent thermal instability and damage to the server, do not separ

Page 75 - Redundant ROM support

Hardware options installation 43 5. Remove the protective cover from the processor. 6. Align the holes in the processor assembly with the guid

Page 76

44 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 7. Install the processor assembly and close the processor locking lever and proc

Page 77 - Diagnostic tools

Hardware options installation 45 NOTE: When configuring the memory sub-system to run in Online Spare mode, only single rank DIMMs can be install

Page 78 - HP Insight Diagnostics

46 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide In the online spare configuration, the ROM automatically configures the last popu

Page 79 - Keeping the system current

Hardware options installation 47 6. Install the DIMM. 7. If removed, reinstall the half-length expansion board ("Installing an expansion

Page 80 - ProLiant Support Packs

48 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Removing a hard drive blank CAUTION: To prevent improper cooling and thermal d

Page 81 - Care Pack

Hardware options installation 49 Installing a SAS or SATA hot-plug hard drive 1. Power down the server ("Powering down the server" on

Page 82

Contents 5 HP Systems Insight Manager...74 Redunda

Page 83 - Battery replacement

50 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide NOTE: Access to the ejector button is intentionally restricted. Push the ejector

Page 84 - 5. Remove the battery

Hardware options installation 51 Redundant hot-plug AC power supply option CAUTION: To prevent improper cooling and thermal damage, do not ope

Page 85 - Troubleshooting

52 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide WARNING: To reduce the risk of electric shock or damage to the equipment, do n

Page 86 - Important safety information

Hardware options installation 53 6. Use the strain relief clip from the server hardware kit to secure the power cord, as illustrated. 7. Route

Page 87 - Troubleshooting 87

54 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide PCI expansion slot definitions Slot* Board Size Connector Interconnect PCI-

Page 88 - Warnings and cautions

Hardware options installation 55 5. Remove the expansion board. Installing an expansion board 1. Power down the server ("Powering down t

Page 89 - Troubleshooting 89

56 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 8. Install the expansion board into the slot until it seats firmly. IMPORTANT:

Page 90

Hardware options installation 57 5. Remove the expansion slot cover from the slot, if installed ("Installing an expansion board" on pa

Page 91 - Loose connections

58 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 8. Identify the differences between the two PCI Express riser boards. It

Page 92 - Diagnostic steps

Hardware options installation 59 a. Install the riser board with the slot for full-length boards onto the assembly. b. Repeat the previous ste

Page 93 - Troubleshooting 93

6 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Regulatory compliance notices 113 Regulatory compliance identification numbers...

Page 95 - General diagnosis flowchart

61 Server cabling In this section Cabling overview...

Page 96

62 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide

Page 97 - Power-on problems flowchart

63 Server software and configuration utilities In this section Configuration tools...

Page 98

64 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • Testing server hardware using the Insight Diagnostics Utility ("HP Insigh

Page 99 - Troubleshooting 99

Server software and configuration utilities 65 Configuration Replication Utility ConRep is shipped in the SmartStart Scripting Toolkit and is a p

Page 100 - POST problems flowchart

66 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • To access RBSU, press the F9 key during power up when prompted in the upper ri

Page 101 - Troubleshooting 101

Server software and configuration utilities 67 For more information, refer to the HP ROM-Based Setup Utility User Guide on the Documentation CD o

Page 102

68 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide For more information on online spare memory, refer to the white paper on the HP w

Page 103 - OS boot problems flowchart

Server software and configuration utilities 69 • Viewing the current logical drive configuration • Deleting a logical drive configuration • Se

Page 104

7 Server component identification In this section Front panel components...

Page 105 - Troubleshooting 105

70 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 3. Select Serial Number. The following warning is displayed: WARNING! WARNING!

Page 106

Server software and configuration utilities 71 Automatic Server Recovery ASR is a feature that causes the system to restart when a catastrophic o

Page 107 - Troubleshooting 107

72 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide IMPORTANT: This utility supports operating systems that may not be supported by

Page 108

Server software and configuration utilities 73 To run iLO RBSU: 1. Restart or power up the server. 2. Press the F8 key when prompted during POS

Page 109 - Other information resources

74 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Run the Erase Utility if you need to erase the system for the following reasons:

Page 110

Server software and configuration utilities 75 Redundant ROM support The server enables you to upgrade or configure the ROM safely with redundant

Page 111 - Electrostatic discharge

76 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 4. Install the access panel ("Extending the server from the rack" on p

Page 112

Server software and configuration utilities 77 • Diagnostics • DOS • Operating environments which do not provide native USB support For more

Page 113

78 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide This utility supports operating systems that may not be supported by the server.

Page 114 - Class A equipment

Server software and configuration utilities 79 Integrated Management Log The IML records hundreds of events and stores them in an easy-to-view fo

Page 115 - Class B equipment

8 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item Description 2 Multi-bay (DVD/CD/Diskette) drive 3 Power on/Standby button a

Page 116 - Modifications

80 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide If you are installing a SmartStart-supported operating system, use the SmartStart

Page 117

Server software and configuration utilities 81 Change control and proactive notification HP offers Change Control and Proactive Notification to n

Page 119 - Laser compliance

83 Battery replacement If the server no longer automatically displays the correct date and time, you may need to replace the battery that provid

Page 120 - Battery replacement notice

84 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide 5. Remove the battery. IMPORTANT: Replacing the system board battery resets th

Page 121

85 Troubleshooting In this section Troubleshooting resources...

Page 122

86 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Server diagnostic steps This section covers the steps to take in order to diagnos

Page 123 - Server specifications

Troubleshooting 87 This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified

Page 124 - Specification

88 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide These symbols, on power supplies or systems, indicate that the equipment is sup

Page 125 - Technical support

Troubleshooting 89 • Do not disable the power cord grounding plug. The grounding plug is an important safety feature. • Plug the power cord into

Page 126

Server component identification 9 Item Description Status 3 Internal health LED Green = System health is normal. Amber = System is degraded. T

Page 127 - Acronyms and abbreviations

90 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Preparing the server for diagnosis 1. Be sure the server is in the proper operat

Page 128

Troubleshooting 91 Symptom information Before troubleshooting a server problem, collect the following information: • What events preceded the fail

Page 129

92 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide • If a fixed cable tray is available for the server, be sure the cords and cable

Page 130

Troubleshooting 93 Item Refer to 1 "General diagnosis flowchart (on page 95)" 2 "Power-on problems flowchart (on page 97)"

Page 131 - Wake-on LAN

94 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide

Page 132

Troubleshooting 95 General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of

Page 133

96 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide

Page 134

Troubleshooting 97 Power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber. • The external

Page 135

98 HP ProLiant DL360 Generation 4p Server (SAS Model) User Guide Item Refer to 5 "Integrated Management Log ("Power-on problems flowcha