Front View:
Rear View:
1.
Access panel
1.
Redundant Power Supply Bay (Optional)
2.
Front LED Indicators
2.
Power Supply Cable Socket
3.
Power on/off
3.
Low Profile Card Slot
4.
Optional DVD-RW or DVD-ROM drive
4.
PCI Expansion Card Slot
5.
Front USB Ports (2)
5.
PCI Expansion Card Slot
6.
Non-Hot Plug Non Redundant fans (4 fans)
6.
UID LED Button
7.
Air Baffle
7.
(Optional) LO100i 10/100 Mbps LAN port for IPMI
management (RJ-45)
8.
PCI Cage
9.
System Board
8.
LAN Port
9.
LAN Port
10.
2 Rear USB 2.0 Ports
11.
VGA Port
12.
Serial Port
What's New
Announcing support for the Intel® Xeon® processor 5600 series-the next generation of intelligent server processors -
offering significant performance (up to 40% over single-core processors), power regulation (Low Voltage DIMMs)
enhancements
Announcing the new High Efficiency server mode.
Support for 750 W and 460 W Platinum Power Supply
Support for I/O Accelerators
At A Glance
The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design
excellence and 2U density for a variety of rack deployments and applications.
Processors
:
Supports up to two Intel® Xeon® Six and Four -Core 5600 sequence processors with up to 12 MB Level 3
cache
Supports up to two Quad-Core Intel® Xeon® processors: 5500 sequence with 8MB Level 3 cache
Intel® 5520 Chipset
Memory
:
Up to 12 DIMM slots
Up to 192GB, using 16GB Quad-Rank PC3-8500R-7 DDR3 Registered (RDIMM) memory, operating at 800MHz
when fully populated at 2 DIMMs per Channel in 12 slots
Up to 96GB, using PC3-10600R DDR3Registered (RDIMM) memory, operating at 1066MHz when fully
populated at 2 DIMMs per Channel in 12 slots.
QuickSpecs
HP ProLiant DL180 Generation 6
Overview
DA - 13248 Worldwide QuickSpecs — Version 22 — 7/13/2010
Page 1
Page view 0
1 2 ... 53

Summary of Contents

Page 1 - QuickSpecs

Front View:Rear View:1.Access panel1.Redundant Power Supply Bay (Optional)2.Front LED Indicators2.Power Supply Cable Socket3.Power on/off3.Low Profile

Page 2

While ProLiant 100 series G6 servers do not support the InsightFoundation Suite for ProLiant, they support a key subset of thisimportant suite softwar

Page 3

HP Insight DiagnosticsAutoRunArray Configuration Utility (ACU) has been combined with ArrayDiagnostics Utility (ADU) to offer both configuration of ar

Page 4

SecurityPower-on passwordSetup passwordDiskette boot controlSecure Sockets Layer (SSL)Secure Shell (SSH)Security - TrustedPlatform ModuleThe TPM (Trus

Page 5

Common Slot ProLiantIt is highly recommended that you use the HP Power Advisor in defining the "Right-Size" powersupply for your needs. HP o

Page 6

Rack KitHP ProLiant DL180 rack models have fixed rails which provide support for racks with roundmounting holes and tool-free support for racks with s

Page 7

Service and SupportHP services provide total care and support expertise with committed response designed to meetyour IT and business needs.HP Care Pac

Page 8

Four Drive Serial ATA (SATA) ModelsNOTE: Upgrading from 4 Non-Hot Plug SATA hard drives to 4 Hot Plug SATA/SAS hard drives requires the addition of as

Page 9

Eight Drive Serial ATA (SATA) ModelsNOTE: Supports up to 8 Hot Plug SATA or SAS Hard Drives.HP DL180G6 E56202x4GB 8LFF590638-xx1ProcessorIntel® Xeon®

Page 10

Form FactorRack (2U)Twelve Drive Serial ATA (SATA) ModelsNOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear Drive Option Kit (P/N 488

Page 11

Internal Storage24.0TB (12 x 2TB Hot Plug 3.5" SATA hard drives), Maximum24.0TB (12 x 2TB Hot Plug 3.5" SAS hard drives), MaximumNOTE: Inter

Page 12

Up to 48GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fullypopulated at 2 DIMMs per Channel in 12 slotsNOTE: Half DIM

Page 13

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only validconfigurations are ordered, HP recomm

Page 14

Step 2: Choose Required Options (only one of the following from each list unlessotherwise noted)HP ProcessorsNOTE: If 2 processors are desired, select

Page 15

HP MemoryRegistered RDIMMsHP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9Memory Kit500656-B21HP 4GB (1x4GB) Dual Rank x4 PC3-10600

Page 16

HP Power SuppliesNOTE: Many HP ProLiant Servers now offer new power options, includingCommon Slot Power Supplies. These power supplies come in multipl

Page 17

NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additionalinformation.HP Unique Options

Page 18

Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066,HT, Turbo 1/1/2/2)508343-B21Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache,

Page 19

HP Optical DrivesHP Slim SATA DVD-ROM Optical Drive481041-B21HP Slim SATA DVDRW Optical Drive481043-B21NOTE: Optical drives can be installed in front,

Page 20

HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive507632-B21HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive

Page 21

HP Entry-Level ServerManagementHP LO100i Advanced Pack, No Media 1-Server License including 1 year of 24x7Technical Support and UpdatesNOTE: For addit

Page 22

HP I/O AcceleratorOptionsHP 160GB SLC PCIe ioDriveNOTE: A low-profile PCI bracket is included for use in low-profile slots.NOTE: A minimum of 4 GB of

Page 23

support web siteExpansion Slots:Up to Four (4) available PCI-Express Slots via the three (3) PCI-E Slot RiserOne available Low Profile x16 PCI-Express

Page 24

512MB BBWCNOTE: Supported on HP Smart Array P410 Controller and HP Smart Array P411Controller only.462967-B21Battery Kit upgradeNOTE: To enable BBWC o

Page 25

HP InfiniBand OptionsQLogic IB 4X QDR PCI-e G2 Dual-port HC583211-B21HP IB 4X QDR CX-2 PCI-e G2 Dual Port HCA592520-B21HP IB 4X DDR CX-2 PCI-e G2 Dual

Page 26

HP Disk BackupNOTE: For the complete range of StorageWorks D2D Backup Systems see:http://www.hp.com/go/d2d. For the complete range of StorageWorks RDX

Page 27

HP U320e SCSI Host Bus AdapterNOTE: Recommended for MSL SCSI Tape Library connect.AH627AStorageWorks Converged Network Adapter HP CN1000E 2P Converged

Page 28

NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/12118_div/12118_d

Page 29

HP Care Pack ServicesHardware Services 4-Hour On-site Service13-Hour x 5-Day Coverage, 3 Years, ElectronicUH271E24-Hour x 7-Day Coverage, 3 Years, Ele

Page 30

NOTE: Memory configurations listed do not apply to "Factory Integrated Models".HP ProLiant DL180 G6Standard Memory (depending on model)4GB (

Page 31

DIMM Type ->Registered DIMMS (RDIMMs)Unbuffered with ECC DIMMs(UDIMMs)DIMM Rank ->SingleRank(1R)Dual Rank (2R)Quad Rank (4R)SingleRank(1R)Dual R

Page 32

Standard memory configuration (1 CPU model)6GB, consisting of three (3) 2GB dual-rank PC3-10600 RDIMMs CPU1 CPU2 slot #population orderslot #populati

Page 33

CPU1 CPU2 slot #population orderslot #population order Chnl 11D: 4GB DIMM1D: emptyChnl 12A: 4GB DIMM2A: empty Chnl 23E: 4GB DIMM3E: emptyC

Page 34

Tool-less access to all system components for easy in rack serviceabilityCustomer Self Repair (CSR): HP products are designed with many CSR parts to m

Page 35

HP MemoryRegistered RDIMMs HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9Memory Kit500656-B21HP 4GB (1x4GB) Dual Rank x4 PC3-10600

Page 36

8 Drive Cage with DVD-Drive bay 1-8Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays9DVD-ROM, DVD RW12 Drive Cage 1-12Twelve 3.5" Hot Plug SA

Page 37

SATA Hot Plug LFF (3.5-inch) Midline (MDL) Drives QuantitySupportedPositionSupportedController2TB 3G SATA 7.2K1TB 3G SATA 7.2K500GB 3G SATA 7.2KUp to

Page 38

HP Smart Array P410/512 MB FBWC ControllerHP Smart Array P410/1G FBWC ControllerHP Smart Array P812/1G FBWC ControllerHP Smart Array Hot Plug Advance

Page 39

QuantitySupportedPositionSupportedController300GB 6G 10K SAS146GB 6G 15K SAS146GB 6G 10K SAS72GB 6G 15K SASUp to 8 with 8drive cage1-8HP Smart Array

Page 40

External Storage QuantitySupportedPositionSupportedController60 Modular Smart ArrayUp to 4ExternalHP Smart Array P212/Zero Memory ControllerHP Smart A

Page 41

LTO-2 Ultrium 448LTO-3 Ultrium 920LTO-4 Ultrium 1760LTO-4 Ultrium 1840LTO-5 Ultrium 3000LTO-5 Ultrium 32801U Rack-Mount Kit3U Rack-Mount Kit HP Stor

Page 42

HP StorageWorks D2DBackup Systems, FibreChannelD2D4000fcRack MountDirect server attach is not supported, requires connection viaSAN fabric. See: http:

Page 43

HP 460W Power SupplyPart Number - AC 460W PSU503296-B21Input Voltage Range (Vrms)100 to 240Frequency Range (Nominal)(Hz)50/60Nominal Input Voltage (Vr

Page 44

HP 460W Platinum PowerSupply Part Number - AC460W PSU593188-B21Input Voltage Range (Vrms)100 to 240Frequency Range (Nominal)(Hz)50/60Nominal Input Vol

Page 45

NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information -Factory Integrated Models&qu

Page 46

System UnitDimensions (H x W x D)(with bezel)3.45" x 17.64" x 28.23" in (8.76 x 44.80 x 71.71 cm)Weight(approximate)Maximum(all hard dr

Page 47

(non-condensing)(82.4°F) maximum wet bulb temperature, non-condensing.Non-operating5 to 95% relative humidity (Rh), 38.7°C(101.7°F) maximum wet bulb t

Page 48

HP 160GB 3G SATA7.2K rpm LFF (3.5-inch)Entry 1yr WarrantyHard Drive458945-B21160GB 7,200 rpmCapacity160,041MBHeight1.04 in (26.4 mm)Width4.36 in (110.

Page 49

Smart Array P410/410iControllerDisk Drive andEnclosure Interface6Gb/s SAS (Serial Attached SCSI)3Gb/s SATA (Serial ATA)SAS Connectors2 internal (Mini-

Page 50

performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotesEnterprise Performance/Wattage (Mainstream)

Page 51

Expansion SlotsSlot NumberBus SpeedBus Number*DeviceNumber**Hot Plug(Y/N)Notes1x16 PCI-Express6 0NLow Profile2x8 PCI-Express5 0NFull LengthFull Height

Page 52

NOTE: A minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Keyupgrade (P/N: 516471-B21) is required to enable RAID 6, 6+0NOTE

Page 53

business. Advanced Licenses are required for Virtual KVM and VirtualMedia feature activation.Key features of LO100 are:IPMI 2.0 & SMASH CLP suppor