Hp ProLiant SL2500 Scalable System User Manual Page 66

  • Download
  • Add to my manuals
  • Print
  • Page
    / 117
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 65
Using SNMP 66
cpqRackPowerSupplyOK
cpqRackPowerSupplyRemoved
cpqRackPowerSupplyInserted
cpqRackServerBladeRemoved
cpqRackServerBladeInserted
* Not supported on HP ProLiant s6500 Chassis
SNMP support of cpqHoSwRunningTable
The first element of this SNMP table lists the HP APM base firmware itself under cpqHoSwRunningName and
cpqHoSwRunningDesc with cpqHoSwRunningVersion listing the correct version of the HP APM firmware.
The following components are listed in the cpqHoSwRunningTable:
SNMP
SSH
syslogd
Telnet
The table entry cpqHoSWRunningState is set to either Running (2) or Stopped (3) to reflect whether that
service is enabled or not. The SNMP service is listed as "Running" when accessed through this MIB item.
All other items in this table are unsupported and will return their respective static return value for “unknown.”
The rows appear in this order:
HP APM base firmware
Telnet
SSH
SNMP
syslogd
The following figure shows a sample table view of cpqHoSwRunningTable.
Page view 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 ... 116 117

Comments to this Manuals

No comments