Chapter 5 Error Message Reference
60
Code Description Recommended Action
failed.
2. Make sure the system board is seated.
3. Check the seating of the voltage regulator module (VRM) if present.
4. Be sure the processor board (if any) is seated.
5. Make sure the CPU chip is seated. (Take ESD precautions.)
6. Make sure the memory elements (DIMMs) are properly seated.
7. Check system fans. If overheating occurs, chip may shut down.
8. If the system ran with temperature high, let it cool for 30 minutes, then restart.
9. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
100Bh Multi Processor
Failure. I/O access
test failed on
processor X at port
XXXXh.
1. Reduce the system to its minimum configuration per the technical reference
label or card.
2. Make sure the system board is seated.
3. Check the seating of the voltage regulator module (VRM) if present.
4. Be sure the processor board (if any) is seated.
5. Make sure the CPU chip is seated. (Take ESD precautions.)
6. Make sure the memory elements (DIMMs) are properly seated.
7. Check system fans. If overheating occurs, chip may shut down.
8. If the system ran with temperature high, let it cool for 30 minutes, then restart.
9. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
100Ch Multi Processor
Failure. Memory
map I/O access test
failed on processor
X at address
XXXXXXXXh.
1. Reduce the system to its minimum configuration per the technical reference
label or card.
2. Make sure the system board is seated.
3. Check the seating of the voltage regulator module (VRM) if present.
4. Be sure the processor board (if any) is seated.
5. Make sure the CPU chip is seated. (Take ESD precautions.)
6. Make sure the memory elements (DIMMs) are properly seated.
7. Check system fans. If overheating occurs, chip may shut down.
8. If the system ran with temperature high, let it cool for 30 minutes, then restart.
9. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
100Dh Multi Processor
Failure. Application
processors were not
detected.
1. Reduce the system to its minimum configuration per the technical reference
label or card.
2. Make sure the system board is seated.
3. Check the seating of the voltage regulator module (VRM) if present.
4. Be sure the processor board (if any) is seated.
5. Make sure the CPU chip is seated. (Take ESD precautions.)
6. Make sure the memory elements (DIMMs) are properly seated.
7. Check system fans. If overheating occurs, chip may shut down.
8. If the system ran with temperature high, let it cool for 30 minutes, then restart.
9. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.
100Eh Multi Processor
Failure. CPU speed
error
1. Reduce the system to its minimum configuration per the technical reference
label or card.