HP ESA10000 User Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
RA7000 / ESA10000 High Availability Solution Kit for HP-UX
1–6 EK–HAHPU–MH. B01
Use Table 1-3 to select the basic cluster layout that best suits your environment.
Prepare and install the SCSI host adapters into your servers (as described in
Section 1.5, “Prepare the SCSI Host Adapters”). Then, reference Chapter 2, –
Cabling the RAID Subsystem Cluster Components,
to proceed with the basic
cluster installation.
1.5 Prepare the SCSI Host Adapters
Each of the host servers in the RAID subsystem cluster requires at least one
supported SCSI host adapter be installed. (Expanding a cluster with a second
RAID subsystem requires two SCSI host adapters per server). Prior to installing
the SCSI host adapter(s) into each server, as described in your HP Host Adapter
installation and service guide, you must prepare each one for a cluster
environment. This involves two main steps:
Setting a unique SCSI host adapter ID
(For Mid-Bus RAID and End-Bus RAID cluster layouts only) Removing the
resistor packs (terminators) on-board the SCSI host adapter
The procedures for setting unique SCSI host adapter IDs and removing resistor
packs from the SCSI host adapters are contained in the following sections. As
you perform these steps, reference the figure that corresponds to your SCSI host
adapter model, as follows:
SCSI Host
Adapter
Illustrated
In
A28696A Figure 1-1
A2969A Figure 1-2
A4107A Figure 1-3
1.5.1 Set Unique SCSI Host Adapter IDs
It is mandatory that each server in a cluster have a unique SCSI host adapter ID
(target ID). The default setting of a SCSI host adapter ID is 7. One of the hosts in
the cluster can maintain this ID. Typically, the SCSI IDs for each added server
should decrease one number from 7, (6, 5, 4, etc.), to ensure that an unused
device number is selected for the server ID.
Use the dip switch on-board the SCSI host adapter(s) to manually set the SCSI
host adapter ID on each host server in the cluster to an unused number. (Two
host adapters in the same server can have the same SCSI ID, as long as the
adapters are not on the same SCSI bus). Reference the Figure for your SCSI host
adapter model to locate the SCSI ID dip switch pack.
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 39 40

Comments to this Manuals

No comments