English 13
HP M900 Monitor User’s Guide
Technical Specifications
Technical Specifications
1. Use the standard image sizes to avoid distortion of the displayed image.
PICTURE TUBE
Size 19-inch flat screen / 18-inch viewable image
Phosphorous Red, Green, Blue short persistence, Dot Type Black Matrix
Dot pitch 0.26 mm
Face Plate Anti-glare, multilayer coating
INPUT SIGNAL
Video 0.660 Vp p analog RGB
Synchronization Separated H/V (TTL level), H/V mixed (TTL level),
Sync-on-green
INTERFACE
Input Connector 15-pin mini D-SUB
SCANNING FREQUENCY
Horizontal 30 to 95kHz
Vertical 50 to 160 Hz
MAX. RESOLUTION (H
×
V)
1600
×
1200 (75 Hz)
WARM-UP TIME
30 minutes to reach optimum performance level
PIXEL CLOCK
200 MHz
IMAGE SIZE
At 1280
×
1024
Standard size
1
: 330(H) x 265(V) mm
Maximum size: 367(H) x 276(V) mm
At other resolutions
Standard size
1
: 355(H) x 265(V) mm
Maximum size: 367(H) x 276(V) mm
POWER SOURCE
AC 90 to 264 V, 47 to 63 Hz, 140W (max), less than 28 W in Standby mode, less than 5 W in Sleep mode,
less than 1 W when switched off.
OPERATING ENVIRONMENT
Temperature 5
°
C to 40
°
C (operating)
- 20
°
C to +60
°
C (storage)
Operating Humidity 10% RH through 80% RH (without condensation)
CABINET DIMENSIONS
454(H)
×
448(W)
×
460(D) mm (with stand)
WEIGHT
25 kg
TILT/SWIVEL STAND
Tilt Angle - 5
°
to +12
°
Swivel Angle
±
60
°
anta.bk : anta-us.fb4 Page 13 Wednesday, July 9, 1997 5:36 PM