HP restrictedHP Ultrium tape drivestechnical reference manualGeneration 3 drivesvolume 5: UNIX configuration guidePart number: Q1538–90925 Volume 5Edi
Introduction10HP restricted
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 112HP-UX systemsHP servers and workstations—HP-UX 11.xNOTE: HP-UX 10.
HP-UX systems12Figure 1 SAM GUIFigure 2 SAM text-based interfaceFor HP-UX 11.11 (11i version 1)1. Enter sam at the command line.2. Select the followin
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 133. Highlight the stape or schgr driver. If the driver has not been
HP-UX systems14ActionsCreate Device FilesCreate Default Device FilesThis will create default device files for the drive. To view the device files that
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 15HP restricted3 HP alpha UNIXHP alpha UNIX 5.x1. Add the following e
HP alpha UNIX16HP restrictedThe device files then have the syntax: tapeX_dnFor example, /dev/ntape/tape66_d1 is a device file for device 66, no-rewind
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 17HP restricted4IBM (AIX)Determining the SCSI IDBefore you configure
IBM (AIX)18HP restrictedOnce device files have been created, you should confirm that your new tape drive is working properly. Chapter 7 on page 27 pro
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 19HP restricted5LinuxDetermining the SCSI ID (Linux)Look at the outpu
HP restrictedLegal and notice information© Copyright 2004–2006 Hewlett-Packard Development Company, L.P.Hewlett-Packard Company makes no warranty of a
Linux20HP restrictedNOTE: To add drivers to the statically built kernel you need the Linux source code available on disk and knowledge of how to use t
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 21HP restrictedWhat next?Once device files have been created, you sho
Linux22HP restricted
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 23HP restricted6 Sun Systems, Solaris 8, 9, 10Determining the SCSI ID
Sun Systems, Solaris 8, 9, 1024HP restrictedIf for some reason you cannot upgrade to the minimum patch level, you can make the following file modifica
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 25HP restrictedHP-Data ValuesThe values for HP_LTO_GEN_n and name, wh
Sun Systems, Solaris 8, 9, 1026HP restrictedValues for the parameters for name are as follows:<no. of densities>4 There are four densities follo
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 27HP restricted7 Verifying the InstallationVerifying the Installation
Verifying the Installation28HP restrictedNOTE: Make sure you prefix the file name with ‘.’ when you back it up to tape. If you do not, the restore ope
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 29HP restrictedGlossaryAT&T mode Berkeley and AT&T functional
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 3HP restrictedRelated documents . . . . . . . . . . . . . . . . . . .
30HP restrictedfibre channel Fibre Channel provides an inexpensive yet expendable means of quickly transferring data between workstations, mainframes,
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 31HP restrictedSingle-Ended and Low Voltage Differential SCSIThese te
32HP restricted
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 33HP restrictedIndexAAIX 17ANSI 5asynchronous data transfer 29AT&a
34HP restrictedUultra SCSI 31Vverifying installation 27Wwide data transfer 29wide SCSI 31
4HP restrictedGlossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Index . . . . . .
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 5HP restrictedRelated documentsThe following documents provide additi
6HP restrictedOperationCartridgesInterfaceOptimizing performance (SCSI only) 1 HW Integration: ch. 8 n/a2 SW Integration: ch. 4UNIX configuration 5 UN
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 7HP restrictedMaintenance and troubleshootingDealing with errorsUltri
8HP restrictedGeneral documents and standardizationSee http://www.t10.org/t10_main.htm for INCITS SCSI Primary Commands—3 (SPC-3) and other specificat
HP Ultrium drives technical reference manual, volume 5: UNIX configuration guide 9HP restricted1IntroductionPurpose of this manualThis manual provides
Comments to this Manuals