Hp Insight Management Agents User Manual Page 36

  • Download
  • Add to my manuals
  • Print
  • Page
    / 157
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 35
Unsupported Drives—One or more attached drives has been determined to be incapable
of properly supporting redundant controller operation.
— Expand in Progress—An expand operation is in progress. Redundant operation not
supported until the expand operation is complete.
— Unknown—Indicates that the Storage Agents are unable to determine the redundancy
error for the controller. You may need to upgrade the Storage Agents.
Firmware Version—Lists the firmware version of the array controller. This value can be
used to help identify a particular revision of the controller.
Product Revision—Displays the revision of the array controller board. This value can be
used to help identify a particular revision of the controller.
Serial Number—Displays the serial number for the array controller. Use this number for
identification purposes.
Processor Usage—Displays the total percentage of the processor usage, expressed as a
number from 0 to 100 inclusive.
Command Count—Displays the total number of read and write commands processed in
this sample. This value is expressed as read and write commands per second.
Command Latency—Displays the average command latency for this sample in 1/100,000 of
a second units.
ADG Enabler Status—Displays the array controller RAID ADG Enabler Module status. The
module enables advanced controller features such as Advanced Data Guarding. The following
values are valid:
— Not Supported—Indicates that the RAID ADG Enabler Module is not supported by
this type of controller.
— Not Present—Indicates that the RAID ADG Enabler Module is not present or is not
accessible.
— Fully Functional—Indicates that the RAID ADG Enabler Module is functional and
accessible.
Bad Signature—Indicates that the RAID ADG Enabler Module has an incorrect signature.
— Bad Checksum—Indicates that the RAID ADG Enabler Module checksum failed.
Present - Upgrade Firmware—Indicates that the RAID ADG Enabler Module is installed,
but a firmware upgrade is required to make it fully functional.
— Unknown—Indicates that the Storage Agents do not recognize the RAID ADG Enabler
Module. You may need to upgrade the Storage Agents.
Daughter Board Type—Displays the type of daughter board installed on the array controller.
The following values are valid:
— Not Supported—Indicates that the array controller does not support daughter boards
or it does not support daughter board identification.
— Not Present—Indicates that a daughter board is not installed on the array controller.
— SCSI—Indicates that a SCSI daughter board is installed on the array controller.
— Fibre—Indicates that a Fibre daughter board is installed on the array controller.
— Array—Indicates that an Array Expansion Module is installed on the array controller.
— Unknown—Indicates that the daughter board type is not recognized. You may need to
upgrade the Storage Agents.
Rebuild Priority—Displays the logical drive rebuild priority of the controller. The following
values are valid:
— Low—Indicates the rebuild priority is low.
— Medium—Indicates the rebuild priority is medium.
— High—Indicates the rebuild priority is high.
— Unknown—Indicates that the rebuild priority is not recognized. You may need to
upgrade the Storage Agents.
36 Agent information
Page view 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 156 157

Comments to this Manuals

No comments