Storage systems
Select a storage system item from the SCSI controller submenu to display the following information
about ProLiant Storage Systems.
Box Type—Displays the type of drive enclosure, or box. The following types of enclosures are
possible:
External Storage System—Outside the machine.
Internal Storage System—Inside the machine.
Unknown—The Storage Agents do not recognize the drive enclosure. You might need to
upgrade your software.
Vendor—Displays the name of the vendor that produces this drive enclosure or box type. Use
this information for identification purposes.
Model—Displays the model of the storage system. Use this information for identification
purposes.
Firmware Revision—Displays the firmware revision of the drive enclosure or box. Use this
information for identification purposes.
Board Revision—Displays the board revision level of this storage system backplane.
Serial Number—Displays the serial number of the drive enclosure or box. Use this information
for identification purposes.
Thermal Status—Displays the temperature status of the drive system. The following values are
possible:
OK—The temperature is within normal operating range.
Degraded—The temperature is outside of normal operating range. Be sure the cover is
on the ProLiant Storage System.
Failed—The temperature is outside of normal operating range, and could permanently
damage the system. Ensure that the fans are spinning and check the room temperature.
Unknown—The Storage Agents do not recognize the thermal status. You might need to
upgrade your software.
No Temperature—This server does not support temperature monitoring.
Fan Status—Displays the status of the fan subsystem in the drive enclosure, or box. The following
values are possible:
OK—The fan subsystem is working properly.
Failed—A fan has failed and there are not enough fans in the fan subsystem to keep the
enclosure cool. Check your fan subsystem as soon as possible. Continued operation might
cause failure of the drives.
Degraded—A fan has failed but there are still enough fans in the fan subsystem to keep
the enclosure cool.
Unknown—The Storage Agents do not recognize the status of the fan subsystem. You
might need to upgrade your software.
No Fan—This server does not have a fan.