HP G2 User Manual Page 110

  • Download
  • Add to my manuals
  • Print
  • Page
    / 153
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 109
110 HP StorageWorks MSA500 G2 Storage System User Guide
86 Drive Position Change Detected
Type: Informational
Description: The physical drive locations have changed for SCSI drives that
constitute a configured volume within the MSA500 G2 storage system. The
controller can no longer access the configured volume.
Action: None
87 Drive Position Change Invalid
Type: Informational
Description: The physical drive locations have changed for SCSI drives that
constitute a configured volume within the MSA500 G2 storage system. The
controller can no longer access the configured volume.
Action:
1. Power down the storage system (on page 28
).
2. Restore the drives to their original positions.
If this action does not solve the problem, contact HP support.
89 Invalid Volume Addition
Type: Error
Description: The controller has detected an illegal volume addition.
Action: Remove the added volume.
Page view 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 152 153

Comments to this Manuals

No comments