HP B110I User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 27
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
Migrating hard drives to an optional Smart Array controller 19
Migrating hard drives to an optional Smart
Array controller
Installing an optional Smart Array controller
To install the component:
1. Power down the server.
2. Remove the access panel.
3. Remove components and cables as needed.
4. Install the Smart Array controller.
For more information, see the server user guide or the documentation that ships with the option.
5. Install components and cables removed previously.
6. Install the access panel.
7. Power up the server.
8. Migrate hard drives to the Smart Array controller:
o Migrating hard drives to an optional Smart Array controllerMicrosoft® Windows® (on
page 19)
o Migrating hard drives to an optional Smart Array controllerLinux (on page 20)
Migrating hard drives to an optional Smart Array
controller—Microsoft® Windows®
This section provides instructions to migrate hard drives from the embedded HP Smart Array B110i SATA
RAID controller to an optional Smart Array controller in a server with a Microsoft® Windows® operating
system.
Installing the Smart Array driverMicrosoft® Windows®
To install the driver from the HP website (http://www.hp.com/go/support):
1. When prompted for product information, enter the Smart Array controller model number in the
product field.
2. Select Download drivers and software.
3. Select the appropriate operating system.
4. Download the HP ProLiant Smart Array SAS/SATA Controller Driver package.
5. To install the driver, run the Smart Array Controller Driver package.
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 25 26 27

Comments to this Manuals

No comments