HP LD4730G 47-inch Micro-Bezel Video Wall Display with Protective Glass User's Guide Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 35
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
COMMAND1 COMMAND2 DATA1 DATA2 DATA3
45. Energy Saving f l 00H–03H
46. Subnet mask (VOE) v g
47. Serial No. f y FFH
48. S/W Verison f z FFH
49. IP Address (NSM) v k
50. Mac Address (VOE) v h
51. Check VOE availability v I FFH
52. Mac Address (NSM) v j
53. Product Name f v FFH
Transmission/Receiving Protocol
Transmission
[Command1][Command2][][Set ID][][Data][Cr]
*[Command 1] First command (k, j, m, d, f, x, v)
*[Command 2] Second command (a to z)
*[Set ID] Set up the Set ID number of product. range: 01H to 63H. by setting
'0', server can control all products.
When operating with more than 2 sets using set ID as '0' at the
same time, do not check the ack message. Because all sets will
send the ack message, it is not possible to check all of the ack
messages.
*[Data] To transmit command data.
Transmit 'FF' data to read status of command.
*[Cr] Carriage Return
ASCII code '0 x 0 D'
*[] ASCII code Space (0 x 20)
OK Acknowledgement
[Command2][][Set ID][][OK][Data][x]
*The Product transmits ACK (acknowledgement) based on this format when receiving normal data. At
this time, if the data is in data read mode, it indicates present status data. If the data is in data write
mode, it returns the data of the media player/computer.