Rosenberger Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com
26
Calibration Kits
RPC-7 Calibration Standards
Electrical Specifications
Devices |
Komponenten
Parameters |
Parameter
Specifications |
Spezifikation
Frequency range in GHz |
Frequenzbereich in GHz
Open circuits
1
| Leerlauf
(male and female)
Return Loss | Rückflussdämpfung
Deviation from Nominal Phase |
Nominale Phasenabweichung
0.10 dB
0.15 dB
1.2°
2.5°
DC to 4
> 4 to 18
DC to 4
> 4 to 18
Short circuits
1
| Kurzschluss
(male and female)
Return Loss | Rückflussdämpfung
Deviation from Nominal Phase |
Nominale Phasenabweichung
0.07 dB
0.12 dB
0.7°
1.5°
DC to 4
> 4 to 18
DC to 4
> 4 to 18
Broadband loads | Breitband-Last
(male and female)
Return Loss | Rückflussdämpfung
Resistance | Gleichstrom-Widerstand
Power Handling | Nennleistung
45 dB
32 dB
50 Ω ± 0.50 Ω
0.5 W (0° to 50° C)
DC to 4
>4 to 18
DC
DC to 18
Sliding loads
2
| Gleitlast Return Loss | Rückflussdämpfung 40 dB 2 to 18
Precision air lines
3
|
Präzisions-Luftleitungen
Return Loss | Rückflussdämpfung
Characteristic Impedance | Wellenwieder-
stand
45 dB
40 dB
50 Ω ± 0.15 Ω
0.3 to 4
> 4 to 18
0.3 to 18
1. The specification for the opens and shorts are given as allowed deviation from the
nominal model as defined in the test report included in the kit.
1. Die Spezifikationen für Leerlauf und Kurzschluss beziehen sich auf die nominale
Phasenabweichung wie im Testreport angegeben (im Kalibrier-Kit enthalten).
2. The specification for the sliding load termination include the quality of the air line
portions within the sliding load combined with the effective stability of the sliding ele-
ment.
2. Die Spezifikationen für die Gleitlast-Abschlüsse beziehen sich auf die Güte des
Luftleitungs-Abschnitts in Verbindung mit der Reproduzierbarkeit des verschiebbaren
Gleitlast-Elements.
3. The characteristic impedance for the air lines is based on mechanical mesure-
ments. The return loss specification includes the connector interfaces. The minimum
frequency of the air lines is based on calculations of the impedance change due to
the skin depth. Refer to the test report included in the kit for the exact dimensions of
your precision air lines.
3. Der angegebene Wellenwiederstand für Luftleitungen basiert auf mechanischen
Messungen, die Rückflussdämpfung schließt das Steckverbinder-Interface mit ein.
Die angegebene minimale Frequenz resultiert aus Berechnungen des aufgrund des
Skin-Effektes frequenzabhängigen Wellenwiederstandes. Bitte beachten Sie den
jedem Kalibrier-Kit beigelegten Testreport.
Rosenberger connectors fulfill in principle the indicated data of the Technical Data.
Individual values of connectors may deviate depending upon application, design,
type of cable, assembly method and execution. Specific data sheets for particular
products can be provided on request from your Rosenberger sales partner.
Rosenberger-Steckverbinder erfüllen grundsätzlich die in den Technischen Daten
angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -aus-
führung können einzelne Werte von Steckverbindern hiervon abweichen. Spezifische
Datenblätter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem Rosenber-
ger-Ansprechpartner.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Calibration Kits

Rosenberger Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com2

Page 2

27Rosenberger Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.co

Page 3

Rosenberger Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com2

Page 4

29Rosenberger Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.co

Comments to this Manuals

No comments