Introducing the HP ProCurve Series 5300xl Switches
Back of the Switch
Introducing the HP ProCurve
Series 5300xl Switches
Back of the Switch
.
Power Connector
The Series 5300xl Switches do not have a power switch; they are powered on
when connected to an active AC power source. The switches automatically
adjust to any voltage between 100-127 and 200-240 volts and either 50 or 60
Hz. There are no voltage range settings required.
Slot for Redundant Power Supply
A second, load-sharing redundant power supply (HP ProCurve Switch gl/xl
RPS, J4839A) can be installed in the back of the Series 5300xl Switches. To
provide true redundancy, this second power supply should be connected to a
different AC power source from the other supply. Then, if one AC power
source fails, the switch will continue to run.
Caution The switch redundant power supply is hot swappable, but, as indicated by the
caution statement on the power supply, it must be disconnected from AC
power before being installed or removed.
Because the switch can run on a single supply, removing a redundant supply
will not interrupt switch operation.
AC power connector
slot for installing optional
redundant power supply
Caution:
.
Refer to the installation guide for proper power cord selection.
.
Disconnect AC power from this power supply BEFORE installing or removing
the supply. Otherwise, damage to the equipment may result.