HP X09 Manual Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
XStreamPKGE™EthernetRFModemProductManualv5.x00[2006.02.24]
4.3. Command Descriptions
Commands in this section are listed alphabetically. Command categories are designated between
the “< >” symbols that follow each command title. XStream Modems expect numerical values in
hexadecimal and those values are designated by a “0x” prefix.
AM (Auto-set MY) Command
<Networking & Security> AM Command is used
to automatically set the MY (Source Address)
parameter from the factory-set modem serial
number. The address is formed with bits 29, 28 and 13-0 of the serial number (in that order).
AT Command: ATAM
Binary Command: 0x3A (58 decimal)
Minimum firmware version required: 4.40
AT (Guard Time After) Command
AT Command: ATAT
Binary Command: 0x05 (5 decimal)
<Command Mode Options> AT Command is
used to set the time-of-silence that follows the
command sequence character (CC Command).
By default, AT Command Mode will activate
after one second of silence.
Parameter Range: 0x02 – 0xFFFF
[x 100 milliseconds]
Number of bytes returned: 2
Default Parameter Value: 0x0A (10 decimal)
Related Commands: BT (Guard Time Before), CC
(Command Sequence Character)
Refer to the AT Command Mode section to view
the default AT Command Mode Sequence.
BD (Interface Data Rate) Command
AT Command: ATBD
Binary Command: 0x15 (21 decimal)
<Serial Interfacing> BD Command allows the
user to adjust the UART interface data rate and
thus modify the rate at which serial data is sent
to the RF modem. The new baud rate does not
take effect until the CN command is issued. The
RF data rate is unaffected by the BD parameter.
Parameter Range (Standard baud rates): 0 – 6
(Non-standard baud rates): 0x7D – 0xFFFF
Parameter
BAUD (bps)
©2006MaxStream,Inc.ConfidentialandProprietary 23
Most applications will require one of the seven
standard baud rates; however, non-standard
baud rates are also supported.
Note: If the serial data rate is set to exceed the
fixed RF data rate of the XStream modem,
flow control may need to be implemented as
described in the Flow Control sections.
Non-standard Interface Data Rates: When
values outside the range of standard baud rates
are sent, the closest rate represented by the
number is stored in the BD register. For example,
a rate of 19200 bps can be set by sending the following command line: ATBD4B00. NOTE: When
using X-CTU Software, non-standard interface data rates can only be set and read using the X-
CTU ‘Terminal’ tab. Non-standard rates are not accessible through the ‘Modem Configuration’ tab.
Configuration
0 1200
1 2400
2 4800
3 9600
4 19200
5 38400
6 57600
Number of bytes returned: 2
Default Parameter Value: Set to equal modem’s
factory-set RF data rate.
Minimum firmware version required: 4.2B
(Custom baud rates not previously supported)
When a non-standard interface data rate is sent, the UART will adjust to accommodate the
requested rate. In most cases, clock resolution will cause the stored BD parameter to vary from
the parameter that was sent (refer to the table below). Reading the BD command will return the
value that was actually stored to the BD register.
Table402. ParameterSentvs.Pa rameterStored
BD Parameter Sent (HEX) Interface Data Rate (bps) BD Parameter Stored (HEX)
0 1200 0
4 19,200 4
7 115,200 7
12C 300 12B
1C200 115,200 1B207
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 55 56

Comments to this Manuals

No comments