HP Fiber-Optic Hub Plus User's Guide Page 50

  • Download
  • Add to my manuals
  • Print
  • Page
    / 84
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 49
Fiber-Optic Cable Requirements
Basic fiber-optic cable specifications are provided here. For more information see the HP
EtherTwist Technical Reference Guide (HP p/n 5091-3237E).
Fiber Specifications. The HP Fiber-Optic Hub Plus supports two different fiber core and
cladding sizes, 62.5/125 µm and 50/125 µm. The hub uses ST connectors.
Fiber Core/Cladding Size 62.5/125mm 50/125mm
Fiber Type Multimode Multimode
Attenuation Grade
4.0 dB/km 4.0 dB/km
Numerical Aperture 0.275 0.20
Modal Bandwidth
150 MHz-km 150 MHz-km
Note: Attenuation and modal bandwidth values are at 850nm wavelength for
both fiber sizes.
Length Limit. The IEEE FOIRL (fiber-optic inter-repeater link) standard limits the length of
the fiber-optic cable between two hubs to one kilometer. In most network configurations, use
the 1-km length maximum as a rule of thumb.
Thin LAN Cable Requirements
The thin coaxial cables used with the HP Fiber-Optic Hub Plus’ ThinLAN port must comply
with the IEEE 802.3 Type 10Base2 requirements. Some RG-58 A/U or RG-58 C/U cable meet
these requirements.
The maximum length of a single thin coaxial cable segment is 185 meters.
A-4 Cables and Connectors
Page view 49