HP AB232A Installation Guide Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
31FCA2384 PCI-X Host Bus Adapter for OpenVMS and Tru64 UNIX Installation Guide
4
Troubleshooting
Power-On Self Test (POST)
The Power-On Self Test (POST) is a troubleshooting utility that you can use for
the FCA2384 host bus adapter (HBA). This chapter explains the use of this utility
in the event of an HBA problem.
Table 6 lists the HBA LED states with descriptions of each state.The position of
the POST LED indicators is defined in Figure 1 and Table 2 of this guide.
If the LEDs indicate a failure during POST:
1. Make sure that the HBA is seated firmly in the PCI slot.
2. Verify that the fibre cable connection to the HBA is secure.
Table 6: POST LED States
Amber LED (L1) Green LED (L2) Description
Off Off Wake-up failure (dead board)
On Off POST failure (dead board)
Slow blink (1 Hz) Off Wake-up failure (dead board)
Fast blink (4 Hz) Off Failure in POST (dead board)
Flashing (irregular) Off POST processing in progress
Off On Failure while functioning
On On Failure while functioning
Slow blink (1 Hz) On Normal—1 Gb link rate
Fast blink (4 Hz) On Normal—2 Gb link rate
Off Blink (1 Hz) Normal—link down or not yet
started
Page view 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 47 48

Comments to this Manuals

No comments