Hp ProLiant DL740 User Manual

Browse online or download User Manual for Computers Hp ProLiant DL740. HP ProLiant DL740 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1.
LED Diagnostic Display (system health and DIMM status)
2.
Unit ID (UID) LED Switch (front and rear)
3.
Universal Media Bay Ejector Button
4.
Redundant Hot Plug Power Supply #2
5.
1.44MB Floppy Drive
6.
Ultra3 Hard Disk Drive Bays (up to four)
7.
CD/DVD-ROM Drive in Universal Media Bay
(hot pluggable)
8.
Redundant Hot Plug Power Supply #1
9.
System Power LED Switch
10.
Processor Board #2
11.
Processor Board #1
12.
Six 100MHz/64-bit PCI-X slots
13.
Redundant Hot Plug Fan #2
14.
Redundant Hot Plug Fan #1
15.
Hot Plug RAID Memory Cartridges (five total)
What's New
What's NewWhat's New
What's New
Intel® Xeon® Processor MP 3.0GHz/4MB, 2.7GHz/2MB, or 2.2GHz/2MB Processors (eight processor capability)
At a Glance
At a GlanceAt a Glance
At a Glance
Uncompromising 8-way performance and availability in an ultra dense, 4U form factor
Intel Xeon Processor MP 3.0GHz/4MB, 2.7GHz/2MB, 2.2GHz/2MB, 2.8 GHz/2MB, 2.5GHz/1MB Processors (eight processor capability)
HP developed F8 chipset
133 MHz SDRAM Memory, expandable to 64 GB addressable memory
HP Hot Plug RAID Memory Technology
Hot Add, Hot Replace, and Hot Upgrade
Uses industry standard ECC-protected memory
Six 64 bit/100MHz PCI-X slots, all hot pluggable
Integrated Lights-Out Standard Management (iLO) on system board
Two NC7781 PCI-X Gigabit NICs (embedded)
Integrated Smart Array 5i Controller (Ultra3 support) (supports RAID 0, 1, 1+0, and 5 across internal hard disk drives)
Internal Hot Plug Drive Storage of 584.2 GB (4 x 1" 146.8-GB Ultra320 hard drives running Wide Ultra3)
Tool less and modular chassis for enhanced serviceability
Innovative diagnostic lighting for rapid response to service events
Unit ID (UID) lighting, front and rear
Front bezel system health/RAID memory LEDs
Two 1100W/800W hot plug redundant power supplies standard
Two hot plug redundant system fans standard
Rapid deployment racking solution (rack rails and cable management)
QuickSpecs
HP ProLiant DL740
HP ProLiant DL740HP ProLiant DL740
HP ProLiant DL740
Overview
DA - 11585 Worldwide — Version 33 — July 16, 2004
Page 1
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - QuickSpecs

1.LED Diagnostic Display (system health and DIMM status)2.Unit ID (UID) LED Switch (front and rear)3.Universal Media Bay Ejector Button4.Redundant H

Page 2

DL740R01 X2.8-2MB,DL740R01 X2.8-2MB,DL740R01 X2.8-2MB,DL740R01 X2.8-2MB,4096MB (4P)4096MB (4P)4096MB (4P)4096MB (4P)330531-xxxProcessor(s)Processor(s)

Page 3

ProLiant DL740 UniqueProLiant DL740 UniqueProLiant DL740 UniqueProLiant DL740 UniqueOptionsOptionsOptionsOptionsLow Line (115V) Cable Kit, C-13 to 5-1

Page 4

ProcessorProcessorProcessorProcessorNOTE:NOTE:NOTE:NOTE: Intel Xeon 3.0GHz/4MB, 2.7GHz/2MB, 2.2GHz/2MB, 2.8GHz/2MB, 2.0GHz/2MB,2.5GHz/1MB, 2.0GHZ/1MB,

Page 5

Storage ControllersStorage ControllersStorage ControllersStorage ControllersSmart Array 532 Controller225338-B21Smart Array 532 Controller (Japan)2253

Page 6

HP StorageWorks Ultrium 215 rack-mount (Carbon) - Single drive installed in a 3U rack-mount kit350544-B21HP StorageWorks Ultrium 215 Array Module (Car

Page 7

HP StorageWorks 3U Rack-Mount Kit274338-B21NOTE:NOTE:NOTE:NOTE: The 3U Rack-Mount Kit can support up to 2 full-height or 4 half-height tape drives and

Page 8

Tape AutoloadersTape AutoloadersTape AutoloadersTape AutoloadersDAT AutoloaderDAT AutoloaderDAT AutoloaderDAT Autoloader HP StorageWorks DAT 40x6

Page 9

HP StorageWorks MSL5052S2 Tape LibraryHP StorageWorks MSL5052S2 Tape LibraryHP StorageWorks MSL5052S2 Tape LibraryHP StorageWorks MSL5052S2 Tape Libr

Page 10

Magneto-OpticalMagneto-OpticalMagneto-OpticalMagneto-OpticalJukeboxesJukeboxesJukeboxesJukeboxesHP StorageWorks 9.1 GB Mid-range Optical JukeboxesHP S

Page 11

Cluster OptionsCluster OptionsCluster OptionsCluster OptionsProLiant Cluster Starter Kit364023-B21NOTE: NOTE: NOTE: NOTE: For additional information r

Page 12

ProcessorProcessorProcessorProcessorOne of the followingdepending on Model:(4) Intel Xeon Processor MP 3.0 GHz/4MB(4) Intel Xeon Processor MP 2.7 GHz/

Page 13

HP StorageWorks ModularHP StorageWorks ModularHP StorageWorks ModularHP StorageWorks ModularSmart Array 1500Smart Array 1500Smart Array 1500Smart Arra

Page 14

Modular PowerModular PowerModular PowerModular PowerDistribution Units - 1U0UDistribution Units - 1U0UDistribution Units - 1U0UDistribution Units - 1U

Page 15

Third Party Rack KitThird Party Rack KitThird Party Rack KitThird Party Rack KitThird Party Rack KitNOTE:NOTE:NOTE:NOTE: The Third party rack kit supp

Page 16

Rack Options for HPRack Options for HPRack Options for HPRack Options for HPRack 10000 SeriesRack 10000 SeriesRack 10000 SeriesRack 10000 Series42U Si

Page 17

HP Factory ExpressHP Factory ExpressHP Factory ExpressHP Factory ExpressFactory Installation, Racking, and Customization ServicesFactory Installation,

Page 18

Installation & Start-Up of a ProLiant server and Microsoft O/S per the Customer Description and/orData Sheet. To be delivered on a scheduled basis

Page 19

(2-5-2 Part Number for Canada)24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Subsequent System Support forWindows NT, Windows 2000, Profes

Page 20

Canada)24 x 7 HW, 2-hr response, Named HW engineer; 24 x 7 Gold Subsequent System Support for NovellNetWare Operating System (6-3 Part Number for U.S.

Page 21

HP ProLiant DL740 2.2GHz/2MB or 2.0GHz/1MB, 2048 MB (4P)HP ProLiant DL740 2.2GHz/2MB or 2.0GHz/1MB, 2048 MB (4P)HP ProLiant DL740 2.2GHz/2MB or 2.0GHz

Page 22

HP ProLiant DL740 3.0 GHz/4MB, 2.7GHz/2MB, 2.8GHz/2MB or 2.5GHz/1MB 4096 MB (4P)HP ProLiant DL740 3.0 GHz/4MB, 2.7GHz/2MB, 2.8GHz/2MB or 2.5GHz/1MB 40

Page 23

Storage ControllersStorage ControllersStorage ControllersStorage ControllersSmart Array 5i Controller (integrated on system board), one internal chann

Page 24

0-31" Ultra3 Hot Plug Drive BaysA1.44-MB Floppy DriveBSlimline CD/DVD-ROM Drive, Hot Pluggable, in Universal Media BayCUniversal Media Bay Eject

Page 25

Maximum Storage Capacity Maximum Storage Capacity Maximum Storage Capacity Maximum Storage Capacity – (StorageWorks Enclosure SCSI Attached) Internal5

Page 26

SSL1016 DLT1 TapeAutoloader MSL6000 (Ultrium 460 -based) Tape LibraryMSL5026S2 (SDLT 320-based) Tape LibraryMSL5052S2 (SDLT 320-based) Tape Libr

Page 27

System UnitSystem UnitSystem UnitSystem UnitDimensions Dimensions Dimensions Dimensions (HxWxD)7.00 x 17.5 x 28.7 in (17.78 x 44.45 x 72.90 cm)WeightW

Page 28

Power SupplyPower SupplyPower SupplyPower Supply1100/800W, Hot Plug1100/800W, Hot Plug1100/800W, Hot Plug1100/800W, Hot PlugRedundant Redundant Redund

Page 29

2352, 2340, 2336, 2048bytes(Mode-1) 2352, 2340, 2336, 2048bytes(Mode-2) Diameter120 mm, 80 mm (with adapter at vertical mounting

Page 30

Two NC7781 PCI-XTwo NC7781 PCI-XTwo NC7781 PCI-XTwo NC7781 PCI-XGigabit NICsGigabit NICsGigabit NICsGigabit NICs(embedded)Network InterfaceNetwork Int

Page 31

ProLiantProLiantProLiantProLiant Essentials Essentials Essentials EssentialsFoundation PackFoundation PackFoundation PackFoundation PackSoftwareSoftwa

Page 32

Industry StandardIndustry StandardIndustry StandardIndustry StandardComplianceComplianceComplianceComplianceACPI 1.0b CompliantPCI-X and PCI 2.2 Compl

Page 33

ServiceabilityServiceabilityServiceabilityServiceabilityInnovative Diagnostic Lighting throughout serverLED display on front bezel indicates system he

Page 34

OS SupportOS SupportOS SupportOS SupportMicrosoft Windows 2000Microsoft Windows 2000 Advanced ServerMicrosoft Windows Server 2003 (Standard and Enterp

Page 35

Service and SupportService and SupportService and SupportService and SupportThree-year limited warranty, including hardware diagnostic support, pre-fa

Page 36

DL740R01 X3.0-4MB,DL740R01 X3.0-4MB,DL740R01 X3.0-4MB,DL740R01 X3.0-4MB,4096MB (4P)4096MB (4P)4096MB (4P)4096MB (4P)348445-xxxProcessor(s)Processor(s)

Comments to this Manuals

No comments