Page 21-25
stack level 7 to give a title to the input string, and leave stack level 6 empty to
facilitate reading the display, we have only stack levels 1 through 5 to define
input variables.
Input string program for two input values
The input string program for two input values, say a and b, looks as follows:
« Enter a and b: {:a::b: {2 0} V } INPUT OBJ »
This program can be easily created by modifying the contents of INPTa. Store
this program into variable INPT2.
Application
: evaluating a function of two variables
Consider the ideal gas law,
pV = nRT, where p = gas pressure (Pa), V = gas
volume(m
3
), n = number of moles (gmol), R = universal gas constant =
8.31451_J/(gmol*K), and T = absolute temperature (K).
We can define the pressure p as a function of two variables, V and T, as
p(V,T) = nRT/V for a given mass of gas since n will also remain constant.
Assume that n = 0.2 gmol, then the function to program is
V
T
K
J
V
T
TVp == )_662902.1(2.031451.8),(
We can define the function by typing the following program
« V T (1.662902_J/K)*(T/V) »
and storing it into variable @@@p@@@.
The next step is to add the input string that will prompt the user for the values
of V and T. To create this input stream, modify the program in @@@p@@@ to read:
« Enter V and T: { :V: :T: {2 0} V }
INPUT OBJ V T (1.662902_J/K)*(T/V) »