Hp 10s Scientific Calculator User Manual

Browse online or download User Manual for PDAs Hp 10s Scientific Calculator. HP 10s Scientific Calculator User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - User's Guide

HP 10s Scientific Calculator User's GuidePart Number: F2214-90001 First Edition: 01/2007m

Page 2

Error Correction when EnteringPress H or E to move the cursor to the position needed.Press H to delete the digit or function at the

Page 3 - Contents

Error Indicator• If an error occurs, press ^ or . The calculation reappears and the cursor is located where the error is. Multi-statementA multi-

Page 4

The display setting (Disp) screen is used to specify the required decimal mark and the character to use before groups of three digits.

Page 5 - Safety Precautions

A negative exponent does not need to be in po rentheses. sin 4.56X 10 “ -► H 4.56 S [t>] 8Example 1:3X(4X10'") = 1.2X10‘3D4SG3 7HExample

Page 6 - Other Precautions

Converting between decimal and fractional displayExample 1: 3.25=3— 3.251(Decimal«—»Fraction) [Example 2:(Fraction«0.2Decimal) 1 S 5 I3.253^1 j4.13

Page 7

Press CD to display the settings screen.Press the number key ( DO or [T] ) corresponding to the setting required:ГП (ab/c ) : Mixed fraction m (

Page 8 - Two-Line Display

Calculations Involving Degrees, Minutes and SecondsYou can convert between sexagesimal and decimal numbers.Example 1: Convert the decimal

Page 9 - Input Limit

(Note that only the display precision gets fixed to 3 digits. The calculations are still performed with the complete number.)100 B 3 I □

Page 10

Calculations Involving the MemoryTo perform a calculation involving the memory, press [m] to enter COMP mode.COMP...

Page 11 - ■ Exponent Display Format

Variable MYou can use the variable M to compute accumulated totals which can be put into the variable M directly, or they can also be ad

Page 12 - Basic Calculations

THIS MANUAL AND ANY EXAMPLES CONTAINED HEREIN ARE PROVIDED "AS IS" AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. HEWLETT-PACKARD COMPANY

Page 13 - El 1.8^1

Scientific FunctionsTo perform a scientific function calculation, press ImeI to enter COMP mode.COMP...

Page 14

Example 1: sinh4.5=45.00301 115@ [¡l!!] 4.5 BExample 2: cosh '60=4.787422291I hr I I SHIFT I [cos'll 60 ^3Hyperbolic and Inverse Hyperbolic

Page 15 - Calculating percentages

Example 3: «/123 (=123'^)= 3.33024571 34 H H 123 BExample 4: 123+45^=2148 1 23 B 45 @ BExample 5: 54^=157464 54@ BExample 6: y—^=62 3 rn2r^P3r

Page 16

Example: Change 2.34 radians to degrees.S...□□ (Deg)2.34 H S H (R)2.34r134.0721241Coordinate Systems (Pol (x,y ), Rec (r ,9))The result w

Page 17 - IshìftI M

Statistics Standard Deviation-SDPress H to select SD mode for statistical calculations with standard deviations.SD...

Page 18 - ■ Ans Memory

Standard deviation of the population(x:on) = 1.316956719 HHEIMean (3c) = 1 3.375 Q Q Q |Number of data points(n) = 8 W W ISum of the data values [x

Page 19 - Variables

Press H to quit the data input operation without storing the entered data values. Alternatively, press GQ to clear the values but remain in da

Page 20 - Scientific Functions

To display the resultPress these keysi»ti imh mSxQ ^nIsiiiFtl iHiiil QzyIsiifl |M| [g □□ZyIsiiiFtl Issiiil rziZxy|»t| IhH rriX[Ml M rnXO nM S HXo n-^M

Page 21 - I SC 4 I ISCDD5

Ai?TemperatureAtmosphericPressureЮЪ1003 hPa15131005 hPa20131010 hPa2513101 1 hPaЗОЮ1014 hPaLinear RegressionThe formula for linear regression is i/=A+

Page 22

Logarithmic, Exponential, Mathematical Power and Inverse RegressionUse these regression types in the same way that you use linear regression (see abov

Page 23 - X 10 " 0.01234

ContentsUsing the Protective Case... 4Safety Precautions...

Page 24 - Statistics

Data Entry Hints# Press to enter the same data twice.• Press H CiD to enter the same data several times. For example, pressing 30 Q 40 [US

Page 25 - Data Entry Hints

Error MessagesIf an error message occurs, the calculator stops running immediately. Press® to clear the error message, or press® or Bto redis

Page 26 - Regression-REG

Input RangeFunctions Input RangeDEGOS |x|s4.499999999x 10'°sinxRAD0s|a:|s785398163.3GRAOS WS4.999999999X 10'°DEG0sWs4.500000008xl0'°cos

Page 27

\/ XW<1X10'°°; ;c7^0n|x|<lX10'°°X!0s^s69 {x is an integer)nPrOsn<l xl0'°,0srsn (n,r are integers) ls{n//(n-r)/}<lXlO'°

Page 28 - I и i!l M я ГП

"it Each operation is accurate to ± 1 in the 10th digit. However, calculations involving multiple operations will cause the error to acc

Page 29 - Quadratic Regression

I In an expression where two components hove the some priority, the calculation is performed from right to left.e*ln^l20 - e* (In ( 120))I Other calc

Page 30 - Technical Data

23®4@ 5©6OXe(e(o+eXo(9+The calculation will be carried out in the order described in Sequence of Operations. During the course of o calculation, the n

Page 31 - ■ Error Messages

^ Disposal of Waste Equipment by Users in Private Households in the European UnionThis symbol on the product or packaging indicates that this pro

Page 32 - Input Range

Regulatory NoticesFederal Communications Commission NoticeThis equipment has been tested and found to comply with the limits for o Class B digita

Page 33

If you have any questions about the product that are notrelated to this declaration, write toHewlett-Packard CompanyP. O. Box 692000, Mail Stop 530113

Page 34 - ■ Sequence of Operations

Variable M...18Variables...

Page 35

JAPANESE NOTICE«è (vcci) ®S2pt*-3<№i: U'CV''S't'i5^i cogg^Sy 1/ t'ÿ g :/gît« tæ® L TÆffl è tL î> i, gît e» êr 51

Page 36 - Specifications

Customer SupportAsia PacificCountry:Telephone numbersAustralia 1300-551-664 or 03-9841-5211China 010-68002397Hong Kong2805-2563Indonesia +65 6100 6682

Page 37

Country: Telephone numbersSouth Africa 0800980410Spain 913753382Sweden08 5199 2065Switzerland022 827 8780 (French)01 439 5358 (Gennan)022 567 5308 (It

Page 38 - FCC Logo, United States Only

Country: Telephone numbersFrench Guiana 0-800-990-011 or 800-711-2884Grenada 1-800-711-2884Guadelupe 0-800-990-011 or 800-711-2884Guatemala 1-800-999-

Page 39 - C€ xxxx* ©

Country: Telephone numbersCanada 800-HP-INVENTUSA (905) 206-4663 or 800-HP INVENT

Page 40 - Warranty Statement

Using the protective casePlease do not slide the protective cose over the LCD.1. Before use, slide the calculator out of the protective cose os shown

Page 41 - Customer Support

NoticeAThis symbol indicates that there is a risk of injury or damage if the specified safety precautions are ignored.Battery9 Keep battery out of

Page 42 - Country: Telephone numbers

when battery power is very low, the calculator's memory may become corrupt or be lost completely. To avoid loss of important in

Page 43

Two-Line DisplayThe calculator shows both the expression being calculated and the result of the calculation. These appear in a two-line d

Page 44

NotesTo return the calculator to its default settings, as indicated below press[sm] ^ ^ (Mode) B in that order. The default settings are

Comments to this Manuals

No comments